Laserfiche WebLink
�1 MONITORING WELL PURGING PROTOCOL <br /> 0 J MEASURE AND RECORD DFPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> OWT <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS USING THE FOLLOWING EQUATION <br /> DO NOT SAMPLE WELL FOR P= a rzh x 7 48 x 3 <br /> DISSOLVED CONSTITUENTS where <br /> P=calculated purge volume(gallons) <br /> n=314 <br /> r=radius of well casing in feet <br /> h=height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL LIMITS THE CALCULATED PURGE VOLUME WHILE <br /> OF DRYNESS BEFORE REMOVING MONITORING GROUNDWATER <br /> CALCULATED PURGE VOLUME STABILIZATION INDICATOR PARAMETERS <br /> (pH, CONDUCTIVITY, TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAME'T'ER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA 1 WELL RECHARGES TO A LEVEL <br /> PH = ± 1 pH units SUFFICIENT FOR SAMPLE <br /> GOND = ± 10 O% COLLECTION WITHIN 24 HOURS <br /> TEMP = ± 1 0 F OF EVACUATION TO DRYNESS <br /> YES NO <br /> X <br /> NO <br /> WELL PURGING CONTINUE PURGING, EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET, ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER,MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING <br /> STABILITY SAMPLING <br /> R FIGURE <br /> EMCON MONITORING WELL PURGING PROTOCOL C-1 <br />