My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2526
>
2800 - Aboveground Petroleum Storage Program
>
PR0529691
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2019 10:37:24 AM
Creation date
10/1/2018 3:03:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0529691
PE
2832
FACILITY_ID
FA0010245
FACILITY_NAME
DTE STOCKTON LLC
STREET_NUMBER
2526
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2526 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.htmi <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> Facility DTE Stockton LLC Facility 2526 W. Washington St., Stockton Date tion <br /> Name: Address: Apr 27, 2012 <br /> Facility Martin Schultze Title: Inst. Controls & Elec. Tech. Ph°r'�209) 320-3715 <br /> Contact: <br /> Inspection XRoutine Ll Follow up Complaint—ID#: 1;Other: <br /> Type: <br /> (Authority HSC 25270.4) <br /> Consentfor: Xlnspection XSampling XPhotos Grantedby: Martin Schultze Title: Ins. Cont. & Elec. Tech <br /> AST DSL USED OIL CLEAN DIRTY LUBE HEAT DIESEL DIESEL Total Facility Shell 13,017 <br /> Content TURBINE TURBINE OIL TRANSFER (GENER) (AIR COMP) Capacity(gal). <br /> Shell 120 477 4000 4000 4000 110 160 150 SPCC Plan 5-year 2�26�08 <br /> Capacity Review Date: <br /> SPCC Plan type: APSA SPCC conditionally exempt(HSC 25270.4.5(b)) Fully or partially Professional Engineer certified i I Self-certified <br /> VIOLATIONS <br /> # I C1 C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1=Class 1 violation,C2=Class 2 violation,M=Minor violation <br /> Aboveground Petroleum Storage Act <br /> 101 HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 <br /> 102 HSC 25270.4.5(a) Failed to conduct periodic inspections of the storage tank to assure compliance with CFR Part 112 <br /> 103 HSC 25270.6(a) Failed to file business plan or annual tank facility statement if capacity>10K gallons and?5% <br /> petroleum <br /> 104 HSC 25270.6(b) Failed to submit APSA fees <br /> 105 HSC 25270.8 Failed to report spills or releases of 42 gallons or more <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112.3(d) SPCC Plan certification by a Professional Engineer(PE)missing or incomplete <br /> 202 CFR 112.3(e) Failed to retain a copy of the SPCC Plan on site <br /> Amendment of SPCC Plan by owners or operators <br /> 301 CFR 112.5(a) Failed to amend SPCC Plan within 6 months,or implement changes within 6 months of amendment <br /> when there is an applicable change to the facility <br /> 302 CFR 112.5(b) Failed to amend SPCC Plan within 6 months,or implement changes within 6 months of amendment <br /> after scheduled 5 year Plan review <br /> 303 CFR 112.5(b) Failed to complete a review and evaluation of SPCC plan at least once every 5 years <br /> 304 jCFR 112.5(c) Failed to have a PE certify technical amendments within 6 months of change <br /> Qualified Facilities Plan Requirements <br /> 401 CFR 112.6(a) Tier I qualified facility failed to self-certify(1)SPCC Plan,(2)technical amendment when there was an <br /> applicable change to the SPCC Plan <br /> 402 CFR 112.6(a)(3) Tier I qualified facility SPCC Plan incomplete <br /> 403 CFR 112.6(b) Tier II qualified facility failed to self-certify(1)SPCC Plan; (2)technical amendment when there was an <br /> applicable change to the SPCC Plan <br /> 404 CFR 112.6(b)(4) Failed to provide written PE certification in a self-certified plan for alternate methods which provide <br /> environmental equivalence,or provisions in lieu of secondary containment due to impracticality <br /> General Requirements for SPCC Plans <br /> 501 CFR 112.7 Failed to include a cross-referencing section for a Plan that does not follow the sequence specified in this <br /> section <br /> 502 CFR 112.7 SPCC Plan lacks full approval of management at a level of authority to commit the necessary resource <br /> to implement the Plan <br /> 503 CFR 112.7(a)(2) Failed to provide equivalent environmental protection and/or state the reasons for nonconformance and <br /> describe the alternate methods and how they achieve equivalent environmental protection <br /> 504 CFR 112.7(a)(3) No facility diagram or diagram failed to show location and contents of each container,transfer stations, <br /> and connecting pipes. <br /> 505 X CFR 112.7(a)(3)(i) SPCC Plan failed to include description of product type and storage capacity for each container <br /> 506 CFR 112.7(a)(3)(ii) SPCC Plan failed to include procedures for routine handling of products and discharge prevention <br /> measures <br /> 507 X CFR 112.7(a)(3)(iii) SPCC Plan failed to show discharge or drainage controls(secondary containment),equipment,and <br /> procedures for the control of a discharge <br /> 508 CFR 112.7(a)(3)(iv) SPCC Plan failed to show countermeasures for discovery,response and cleanup of discharges <br /> Inspector Received By: Title: <br /> Stacy Rivera (209) 468-3440 <br /> EHD 28-02 Rev 09/01/11 Page 1 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.