My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2526
>
2800 - Aboveground Petroleum Storage Program
>
PR0529691
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2019 10:37:24 AM
Creation date
10/1/2018 3:03:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0529691
PE
2832
FACILITY_ID
FA0010245
FACILITY_NAME
DTE STOCKTON LLC
STREET_NUMBER
2526
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2526 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sagov.orci/ehd/unitiii.html <br /> CONTINUATION FORM Page: 4 of 4 <br /> OFFICIAL INSPECTION REPORT Date: 04/27/12 <br /> Facility Address: 2526 W. Washington St., Stockton Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> 505, 507 & 513. The inventory listed in the SPCC Plan does not include the emergency generator or the <br /> air compressor. Discharge & drainage controls and potential equipment failure are not addressed for <br /> any of the unlisted containers. The SPCC Plan must include the correct type of oil and storage capacity <br /> of each fixed storage container, and either the type of oil and storage capacity of each portable container <br /> or an estimate of the potential number of portable containers, types of oil, and anticipated storage <br /> capacities. The Plan must include discharge or drainage controls, such as secondary containment <br /> around all containers and other structures, equipment, and procedures for the control of a discharge, <br /> and a prediction of the direction, rate of flow, and total quantity of oil which could be discharged as a <br /> result of each type of major equipment failure. Immediately update the inventory and discharge <br /> information in the SPCC Plan to accurately represent the petroleum storage at the facility. <br /> 510. The phone number for the San Joaquin County Office of Emergency Services is outdated. The <br /> SPCC Plan must include a contact list and phone numbers for the facility response coordinator, National <br /> Response Center, cleanup contractors with whom you have an agreement for response, and all <br /> appropriate federal, state, and local agencies who must be contacted in case of a discharge. <br /> Immediately update the contact list to include the most current version of the required information. <br /> 517. Daily inspections are not being conducted on the aboveground tanks. Monthly inspections are <br /> being conducted, but the inspection reports have not been completed. Inspections and testing shall be <br /> conducted on all aboveground liquid petroleum containers larger than 55 gallons. Records of these <br /> inspections and tests shall be signed by the appropriate supervisor or inspector and kept on site with the <br /> SPCC Plan for a period of three years. Immediately begin necessary testing and inspections for all <br /> APSA regulated containers and maintain copies of the inspection records on site with the SPCC Plan. <br /> 609. Integrity testing has not been conducted on the aboveground petroleum tanks and is only <br /> addressed in the SPCC Plan for the previous 75,000 gallon diesel tank. The facility shall test or inspect <br /> each aboveground container for integrity in accordance with industry standards. Comparison records <br /> and other records of inspections and tests must be maintained on site with the SPCC Plan. Immediately <br /> conduct all necessary integrity testing and maintain records on site as required. <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by May 27, 2012 <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> Provided: Return to Compliance Certification form <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received BY: Title: <br /> Stacy Rivera (209) 468-3440 A�4T <br /> EHD 23-02-003 Rev 07/12/11 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.