My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2201
>
2800 - Aboveground Petroleum Storage Program
>
PR0538721
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 2:23:20 PM
Creation date
10/1/2018 3:44:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0538721
PE
2832
FACILITY_ID
FA0009480
FACILITY_NAME
STOCKTON PORT DIST
STREET_NUMBER
2201
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14502004/162030
CURRENT_STATUS
01
SITE_LOCATION
2201 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STI SP001 Portable Container Monthly Inspection Checklist <br />Inspection Date:y 6 F t Retain Until Date: w <br />Prior Inspection Date: _� I `-f 1 1: Inspector Name <br />Containers Inspected (ID #'s): <br />Q. N a,J O,Y'C6 <br />(36 months from inspection date) <br />Building 804 (AST -4, AST -5, AST -6, Drums) Generators (AST -3, AST -10 <br />through AST -14), Trailer (AST -15) <br />Inspection Guidance: <br />i For equipment not included in this Standard, follow the manufacturer recommended inspection/testing <br />schedules and procedures. <br />The periodic AST Inspection is intended for monitoring the external AST condition and its containment <br />structure. This visual inspection does not require a Certified Inspector. It shall be performed by an owner's <br />inspector who is familiar with the site and can identify changes and developing problems. <br />(*) designates an item in a non-conformance status. This indicates that action is required to address a <br />problem. <br />:- Non -conforming items important to tank or containment integrity require evaluation by an engineer <br />experienced in AST design, a Certified Inspector, or a tank manufacturer who will determine the corrective <br />action. Note the non-conformance and corresponding corrective action in the comment section. <br />i Retain the completed checklists for 36 months. <br />Item <br />I Area: Building 804 <br />Area: Building 120 1 <br />Area: Mobile Generators <br />Area: TM1* J{ <br />1.0 AST Containment/Storage Area <br />1.1 Containers within <br />No* <br />Yes <br />No <br />> Yes <br />No* <br />?d es <br />No* <br />designated storage area? <br />1.2 Debris, spills, or other fire <br />hazards in containment <br />Yes* <br />Ao <br />Yes* <br />KIN <br />Yes* <br />74V0 <br />Yes* <br />Vo <br />or storage area? <br />1.3 Water in outdoor <br />Yes* <br />No )(,N/A <br />Yes* <br />No /A <br />Yes* <br />Nol/A <br />Yes* Flo <br />N/A <br />secondary containment? <br />1.4 Drain valves operable <br />and in a closed <br />)<%es <br />No <br />,4es <br />No <br />X'es <br />No <br />X'es <br />No <br />position? <br />1.5 Egress pathways clear <br />and gates/doors <br /><es <br />No <br />' 'es <br />No <br />�qes <br />No <br />x(es <br />No <br />operable? <br />2.0 Leak Detection <br />2.1 Visible signs of <br />leakage around the <br />Yes <br />XNo <br />Yes <br />o <br />Yes* <br />No <br />Yeso <br />container or <br />storage area? <br />3.0 Container <br />3.1 Noticeable container <br />distortions, buckling, <br />Yes* <br />><No <br />Yes* <br />Xqo <br />Yes* <br />'xNo <br />Yes* <br />0 <br />denting or bulging? <br />v <br />
The URL can be used to link to this page
Your browser does not support the video tag.