My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
5749
>
2800 - Aboveground Petroleum Storage Program
>
PR0515802
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2019 10:26:15 AM
Creation date
10/2/2018 10:02:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0515802
PE
2832
FACILITY_ID
FA0021241
FACILITY_NAME
TRACY MUNICIPAL AIRPORT
STREET_NUMBER
5749
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5749 S TRACY BLVD
P_DISTRICT
005
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY MUNICIPAL AIRPORT 5749 S TRACY BLVD, TRACY September 22, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 612 CFR 112.7(c) Plan failed to include secondary containment, diversionary structures, or equip to prevent discharge. <br /> The SPCC plan stated that the 55 gallon used oil drums"containment has not been designed to provide sufficient <br /> "available capacity"for a spill." Secondary containment was observed for the two used oil drums in the form of <br /> overpack drums. The SPCC plan needs to discuss the secondary containment for each aboveground petroleum <br /> storage container larger than 55 gallons. Immediately update the SPCC plan to discuss the secondary containment <br /> for all aboveground petroleum storage containers larger than 55 gallons. <br /> This is a Class II violation. <br /> 618 CFR 112.7(e), 112.8(c)(6) Failed to conduct inspections or integrity tests or maintain records for 3 years. <br /> Copies of inspection and testing records for the last three years were not found on site. Inspections and tests must <br /> be conducted in accordance with the written procedures developed in the Spill Prevention, Control, and <br /> Countermeasure(SPCC)Plan. Records of these inspections and tests must be signed by the appropriate <br /> supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately locate a copy <br /> of all inspection and testing records for the last three years, maintain them on site,and submit copies to the EHD. <br /> This is a repeat violation,Class ll. <br /> 619 CFR 112.7(0(1) Failed to train personnel on discharge prevention. <br /> Oil handling personnel were not trained. At a minimum, oil handling personnel shall be trained in the operation and <br /> maintenance of equipment to prevent discharges;discharge procedure protocols; applicable pollution control laws, <br /> rules, and regulations; general facility operations; and the contents of the Spill Prevention, Control, and <br /> Countermeasure Plan. Immediately provide this training to all oil handling personnel and submit a copy of the <br /> training log to the EHD. <br /> This is a repeat violation, Class II. <br /> 622 CFR 112.7(f)(3) Failure to conduct spill prevention briefing for oil-handling personnel. <br /> Discharge prevention briefings are not scheduled at least once a year. Discharge prevention briefings for oil <br /> handling personnel must be scheduled and conducted at least once a year to assure adequate understanding of the <br /> SPCC Plan for that facility. Such briefings must highlight and describe known discharges or failures, malfunctioning <br /> components, and any recently developed precautionary measures. Immediately schedule and conduct a discharge <br /> prevention briefing, ensure that they are scheduled and conducted at least once a year. <br /> This is a repeat violation, Class Il. <br /> FACO21241 PR0515802 SCO01 09/22/2017 <br /> EHD 28-01 Rev.09/22/16 Page 6 of 8 Aboveground Petroleum Storage Act OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.