My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15453
>
2800 - Aboveground Petroleum Storage Program
>
PR0523476
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2019 3:19:48 PM
Creation date
10/2/2018 11:28:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523476
PE
2832
FACILITY_ID
FA0015491
FACILITY_NAME
PROFLEET TRUCK LUBE
STREET_NUMBER
15453
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
APN
02519006
CURRENT_STATUS
01
SITE_LOCATION
15453 N THORNTON RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M cKennyKrugs- <br /> Design of containment area: <br /> Perimeter wall(Pm=1500): 2'-10"high 6"CMU wall w/#4 @ 32"o.c. v, and <br /> min. (2) #4 h. T&B <br /> Wall Check: M = 83#-Ft V = 88# <br /> j=0.9, k=0.29, d=2.81, Fm=1500, Em=2850000 <br /> Bending: fs=5.2ksi<Fs=20ksi, <br /> fb=81 psi<Fb=250psi <br /> Shear: fv=2.88psi<Fv=19.36psi <br /> Concrete Slab (f c=2500) 6"slab w/#3 @ 18"EW <br /> Perimeter Footing (f c=2500): 18"x24"concrete footings w/#4 T&B <br /> Concrete slab and CMU walls are more than capable of retaining the oil spill <br /> based on the design parameters specified. <br /> Visual inspection of containment area <br /> Containment area is sound <br /> Site Security: <br /> Authorized personnel provide security during operational hours. Site lighting is <br /> provided at night with all tanks, pumps and starter controls locked down during <br /> nonoperational hours. <br /> Secondary Containment findings: The secondary containment system is of <br /> sufficient capacity and condition for the containment of releases from tanks and <br /> ancillary equipment based on design parameters specified. Initials: <br /> STRUCTURAL & CIVIL ENGINEERING • CODE APPLICATIONS <br /> PHONE:(916)866-0762 <br /> 60205ACRAMENTO8ifgi FAX:(916)966-076] <br /> 626 <br /> FAIR OAKS,CA 96 <br /> hltp:/lww w.mekNvtyknp.tom <br />