COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
520
>
2800 - Aboveground Petroleum Storage Program
>
PR0528294
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2019 11:42:09 AM
Creation date
10/2/2018 11:34:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528294
PE
2832
FACILITY_ID
FA0009384
FACILITY_NAME
CITY OF TRACY BOYD SERVICE CTR
STREET_NUMBER
520
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23538001
CURRENT_STATUS
01
SITE_LOCATION
520 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CITY OF TRACY BOYD SERVICE CTR 520 S TRACY BLVD,TRACY September 25, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CFR 112.7 Failure of Plan to fulfill basic requirements including a cross-referencing section. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not follow the order or requirements in 40 <br /> CFR Part 112, and a cross-reference was not provided. If you do not follow the sequence specified in 40 CFR 112 <br /> for the Plan, you must prepare an equivalent Plan and supplement it with a section cross-referencing the location of <br /> requirements in 40 CFR 112 and the equivalent Plan. Immediately amend the SPCC Plan to include a <br /> cross-reference or to follow the required sequence. <br /> This is a minor violation. <br /> 603 CFR 112.7(a)(3)Failed to adequately describe the physical layout of the facility in the Plan. <br /> The location and contents of the tank associated with the emergency generator and the hydraulic lift were not shown <br /> on the facility diagram, also, the connecting piping (underground piping)was not shown on the facility diagram. The <br /> Spill Prevention, Control, and Countermeasure(SPCC) Plan shall include a facility diagram which must mark the <br /> location and contents of each fixed storage container and the storage area where mobile or portable containers are <br /> located. It must identify the location of and mark as"exempt"underground tanks. It must also include all transfer <br /> stations and connecting pipes, including intra-facility gathering lines. Immediately update the facility diagram to <br /> include all of the required information. Submit a legible copy of the updated facility diagram to the EHD for review. <br /> This is a Class II violation. <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not provide information for the phone <br /> number for the cleanup contractor. If a response plan was not submitted to the Regional Administrator,this <br /> information must be included in the SPCC Plan. Contact list and phone numbers for the facility response <br /> coordinator, National Response Center, cleanup contractors with whom you have an agreement for response, and <br /> all appropriate Federal, State, and local agencies who must be contacted in case of a discharge Immediately <br /> amend the SPCC Plan to include this information and submit a copy of the revision to the EHD. <br /> This is a minor violation. <br /> FA0009384 PR0528294 SCO01 09/25/2018 <br /> EHD 28-01 Rev.09/10/2018 Page 5 of 8 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.