My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2131
>
2800 - Aboveground Petroleum Storage Program
>
PR0535925
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2019 11:37:12 AM
Creation date
10/2/2018 11:43:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0535925
PE
2833
FACILITY_ID
FA0009893
FACILITY_NAME
NORTHERN CALIF POWER - LODI
STREET_NUMBER
2131
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2131 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMCMU <br /> San Joaquin County I <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sj,oq v_orp/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NORTHERN CALIF POWER- LODI 2131 W TURNER RD, LODI January 06, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 605 CFR 112.7(x)(3) Plan failed to address facility layout, operations discharge prevention methods and containers. <br /> The contact number of the facility response coordinator was not indicated in the plan. The following shall be <br /> addressed in the Spill Prevention, Control, and Countermeasure(SPCC) Plan: <br /> -type of oil in each fixed container and it's storage capacity. For mobile or potable containers, the type of oil and <br /> storage capacity for each container or an estimate of the potential number of mobile or portable containers, the <br /> types of oil, and anticipated storage capacities <br /> -discharge prevention measures including procedures for routine handling of products <br /> -discharge or drainage controls such as secondary containment, equipment, and procedures for the control of a <br /> discharge <br /> -countermeasures for discharge discovery, response, and cleanup <br /> - methods of disposal of recovered materials <br /> -contact list and phone numbers for the facility response coordinator, National Response Center, cleanup <br /> contractors, and all appropriate Federal, State, and local agencies. <br /> Immediately amend the SPCC Plan to include all required information. <br /> This is a Class II violation. <br /> 609 CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge. <br /> The mortar applied to the secondary containment wall of the 138,600 gallon diesel storage tank has cracks in it. It <br /> appears that its integrity has been compromised. A facility shall provide appropriate containment and/or <br /> diversionary structures or equipment to prevent a discharge. The entire containment system, including walls and <br /> floor, must be capable of containing oil and must be constructed so that any discharge from a primary containment <br /> system will not escape the containment system before cleanup occurs. Immediately provide adequate secondary <br /> containment for all aboveground petroleum storage containers larger than 55 gallons. <br /> This is a Class II violation. <br /> 613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years. <br /> Copies of inspection and testing records did not include all of the requirements indicated in the facility Spill <br /> Prevention, Control, and Countermeasure (SPCC) plan were not found on site. Inspections and tests must be <br /> conducted in accordance with the written procedures developed in the Spill Prevention, Control, and <br /> Countermeasure (SPCC) Plan. Records of these inspections and tests must be signed by the appropriate <br /> supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately locate a copy <br /> of all inspection and testing records for the last three years, maintain them on site, and submit copies to the EHD. <br /> This is a Class II violation. <br /> 704 CFR 112.8(c)(2) Diked area is not sufficiently impervious to contain discharged oil. <br /> The mortar applied to the secondary containment wall of the 138,600 gallon diesel storage tank has cracks in it. It <br /> appears that its integrity has been compromised and is not impervious to contain discharged oil. Diked areas must <br /> be sufficiently impervious to contain discharged oil. Immediately provide or repair all diked areas to be sufficiently <br /> impervious to contain oil. <br /> This is a Class II violation. <br /> Received spy Inspector: Phone: Date: <br /> (initial): ��, � (�� ARIS VELOSO, Senior REHS (209)468-3453 01/06/2016 <br /> Page 4 of 6 <br />
The URL can be used to link to this page