My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO 2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 2:54:01 PM
Creation date
10/4/2018 3:59:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2010-2015
FileName_PostFix
2010-2015
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
TRACY PETRO INC*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�.J TANK #: 1 <br /> IN-TANK ALARMS <br /> T 1 :HIGH WATER ALARM <br /> T 1 :LOW PRODUCT ALARM <br /> LIQUID SENSOR SETUP OUTPUT RELAY SETUP - - LIQUID SENSOR ALMS <br /> L 6:FUEL ALARM <br /> - - - - - - - - L 9:FUEL ALARM <br /> L 1 :87 ANN. R 1 :87 RELAY L10:FUEL ALARM <br /> DUAL POINT HYDROSTATIC TYPE: L11 :FUEL ALARM <br /> CATEGORY : ANNULAR SPACE STANDARD L12:FUEL ALARM <br /> NORMALLY CLOSED L 6:SENSOR OUT ALARM <br /> L 9:SENSOR OUT ALARM <br /> TANK #: 2 L10:SENSOR OUT ALARM <br /> L 2:87 FILL SUMP L11 :SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L12:SENSOR OUT ALARM <br /> CATEGORY PIPING SUMP IN-TANK ALARMS L 6:SHORT ALARM <br /> T 2:HIGH WATER ALARM L 9:SHORT ALARM <br /> T 2:LOW PRODUCT ALARM L10:SHORT ALARM <br /> L 3:87 STP SUMP Lll :SHORT ALARM <br /> TRISTATE (SINGLE FLOAT) LIQUID SENSOR ALMS L12:SHORT ALARM <br /> CATEGORY : STP SUMP L 9:FUEL ALARM <br /> L 9:FUEL ALARM ISD SITE ALARMS <br /> L10:FUEL ALARM ISD GROSS PRES FAIL <br /> L 4:DIESEL STP SUMP Lll :FUEL ALARM ISD DEGRD PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) L12:FUEL ALARM ISD VAPOR LEAK FAIL <br /> CATEGORY : STP SUMP L 3:SENSOR OUT ALARM ISD VP PRES FAIL <br /> L 9:SENSOR OUT ALARM ISD VP STATUS FAIL <br /> LIO:SENSOR OUT ALARM ISD SETUP FAIL <br /> L 5:DIESEL FILL SUMP LII :SENSOR OUT ALARM ISD SENSOR OUT FAIL <br /> TRI-STATE (SINGLE FLOAT) L12:SENSOR OUT ALARM <br /> CATEGORY PIPING SUMP L 3:SHORT ALARM ISD HOSE ALARMS <br /> L 9:SHORT ALARM ALL:FLOW COLLECT FAIL <br /> L10:SHORT ALARM <br /> L 6:91 STP SUMP Lll :SHORT ALARM R 4:OVERFILL ALARM <br /> TRI-STATE (SINGLE FLOAT) L12:SHORT ALARM TYPE: <br /> CATEGORY : STP SUMP STANDARD <br /> ISD SITE ALRRMS NORMALLY OPEN <br /> ISD GROSS PRES FAIL <br /> L 7:91 FILL SUMP ISD DEGRD PRES FAIL TANK #: NONE <br /> TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> CATEGORY : PIPING SUMP ISD VP PRES FOIL <br /> ISD VP STATUS FAIL IN-TANK ALARMS <br /> ISD SETUP FAIL ALL:OVERFILL ALARM <br /> L 8:91 ANN. ISD SENSOR OUT FAIL ALL:HIGH PRODUCT ALARM <br /> DUAL POINT HYDROSTATIC ALL:MAX PRODUCT ALARM <br /> I <br /> CATEGORY : ANNULAR SPACE SD HOSE ALARMS <br /> ALL:FLOW COLLECT FAIL <br /> R 2:DIESEL RELAY <br /> L 9:DISP. 1-2 TYPE: <br /> TRI-STATE (SINGLE FLOAT) STANDARD <br /> CATEGORY : DISPENSER PAN NORMALLY CLOSED <br /> TANK #: 3 <br /> L10:DISP.3-4 IN-TANK ALARMS SMARTSENSOR SETUP <br /> TRI-STATE (SINGLE FLOAT) T 3:HIGH WATER ALARM - - - - - - - - - - - - <br /> CATEGORY DISPENSER PAN T 3:LOW PRODUCT ALARM <br /> s 1 :1-2 AFM <br /> LIQUID SENSOR ALMS CATEGORY AIR FLOW METER <br /> L11 :DISP. 5-6 L 4:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L11 :FUEL ALARM s 2:3-4 AFM <br /> CATEGORY : DISPENSER PAN L12:FUEL ALARM CATEGORY AIR FLOW METER <br /> L 4:SENSOR OUT ALARM <br /> Lll :SENSOR OUT ALARM s 3:5-6 AFM <br /> L12:SENSOR OUT ALARM CATEGORY AIR FLOW METER <br /> L12:DISP. 7-8 L 4:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) LII :SHORT ALARM s 4:7-8 AFM <br /> CATEGORY : DISPENSER PAN L12:SHORT ALARM CATEGORY AIR FLOW METER <br /> R 3:91 RELAY s 5:PRESSURE SENSOR 5-6 <br /> TYPE: CATEGORY VAPOR PRESSURE <br /> STANDARD <br /> NORMALLY CLOSED s 6:POLISHER <br /> CATEGORY VAPOR VALVE <br /> s B:ATM P <br /> CATEGORY ATM P SENSOR <br />
The URL can be used to link to this page
Your browser does not support the video tag.