Laserfiche WebLink
Appendix VI <br /> RECEIVED <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://Www.swreb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION APR 01 2014 <br /> For Use By All Jurisdictions Within the State of California NMENTAL <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, Cal/for DEPARTMENT <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: TRACY PETRO Bldg.No.: <br /> Site Address: 3400 N.MACARTHUR DR City: TRACY Zip: 95376 <br /> Facility Contact Person: KARAM SINGH Contact Phone No.: 209-814-8581 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 2/21/2014 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: TI-PREMIUM Tank ID: T3-Diesel <br /> rV In-Tank Gauging Probe. Model: mag r' In-Tank Gauging Probe. Model: mag <br /> Annular Space or Vault Sensor. Model: 303 W: Annular Space or Vault Sensor. Model: 303 <br /> (70 Piping Sump/Trench Sensor(s). Model: 208 P-0 Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: 208 <br /> r Mechanical Line Leak Detector. Model: Vaporiess LD-2000 ry—,. Mechanical Line Leak Detector. Model: Vaporless LD-2000 <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> WO Tank Overfill/High-Level Sensor.Model flapper (✓• Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment a and model in Section E on Pa e 2 . Others ui ment type and model in Section E on Pae 2). <br /> Tank ID: T2-REGULAR Tank ID: <br /> WO In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: 303 r Annular Space or Vault Sensor. Model: <br /> (1/_ Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> WO Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: <br /> P Mechanical Line Leak Detector. Model: Vapodess LD-2000 r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment type a r Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 7/8 <br /> ID: ID: <br /> r7 Dispenser Containment Sensor(s).Model: 208 WO Dispenser Containment Sensor(s).Model: 208 <br /> Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Floats and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 3/4 Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: <br /> W Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Floats and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser <br /> ID: ID: <br /> P-0 Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: <br /> WO Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this forn.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certfy that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturerschecklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that appal.r.System set- <br /> up r Alarm history report <br /> Technician Name(print): Brent Bowen Signature: <br /> Certification No.: 842815 License.No.: 7431600a5 'A <br /> Testing Company Name: Tanknology Phone No.: (800)BOD4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/21/2014 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />