ow <br /> 59' <br /> 32' GANTRY TRACK 4' <br /> 3' TO 5' <br /> 4' <br /> PER SITE 2 <br /> ENGINEER 2e-7211 SH4 <br /> vv <br /> aLawL-41 11I LI <br /> - A ml III rw <br /> GR C. _- <br /> 4" OVERFLOW TO O.W.S. <br /> BACKFLOW PREVENTER REQ'D <br /> 10'_L) <br /> 71 <br /> oc <br /> 2"OVERFLOW FROM 2' i <br /> p 7 —1 ABOVE GROUND TANK 5 i {� <br /> 15'-3" - WASHBAY1"FROM RECLAIM SYSTEM ( { I ` .MAC <br /> UNDERFLOW LINE NOTE: H-20 OPEN GRATE i TRA E <br /> NOTSHOWN I � <br /> ' 2,T� 1"WIRE ONDUIT '�g_ '� I <br /> 1 <br /> GROUND RECLAIM TANK 1 --- ----- SH4 <br /> _ GR CES <br /> MS <br /> Ilz CHEMICAL CONTAINERS <br /> a . auu -2 1-1011 S <br /> o FR O { { 10' TO 12' <br /> G r i { PER SITE ENGINEER <br /> c S,,, . <br /> ZERO DISCHARGE SYSTEM WITH (2) 750 GALLON TANKS <br /> 9,-�1e (5) 500 GALLON CONICAL BOTTOM RECLAIM WATER STORAGE TANKS <br /> li <br /> EQUIPMENT ROOM { <br /> [ER-000i <br /> o i O � 0 PW2005MXX0 WITH AOS <br /> TANK1 TANK2 { TANK TANK TANK5 co EQUIPMENT LEGEND <br /> AC AIR COMPRESSOR <br /> AS AIR SWITCH <br /> CES CODED ENTRY SYSTEM <br /> CPO CPO CONTROLLER <br /> 24' ORIGINAL DESIGN sow DC DOOR CONTROLS <br /> DR DRYER CONTROL BOX <br /> 50 DT DRYER TIMER <br /> EC ENERGY CHAIN FEED SYSTEM <br /> EP ELECTRICAL PANEL (BY OTHERS) <br /> FD FS-40D FREESTANDING DRYER <br /> FR FINAL RINSE PUMP <br /> GR GUIDE RAILS <br /> IS INSTRUCTION SIGN <br /> JB IN-BAY JUNCTION BOX <br /> MD MAIN DISCONNECT <br /> MS MERCHANDISING SIGN <br /> RP R/O RECAPTURE PUMP <br /> RO R/O UNIT <br /> DRAWING NOTES GENERAL NOTES RS REPRESSURIZATION SYSTEM <br /> RU RECLAIM UNIT <br /> T <br /> 1} THE EQUIPMENT ROOM WALL THAT SUPPORTS ENERGY CHAIN, HIS DRAWING IS THE PROPERTY OF MARK VII EQUIPMENT, INC.MARK VII EQUIPMENT, INC. IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS SF SPOT FREE STORAGE TANK <br /> NEEDS BE STRUCTURALLY DESIGNED (BY OTHERS) TO SUPPORT AT BASED ON LOCAL CODES OR CONDITIONS, THEREFORE DRAWINGS MUST BE SFR SPOT FREE REJECT PUMP <br /> LEAST 45050 lbs. <br /> 2) INSTALLATION OF EQUIPMENT REQUIRES THE USE OF CONCRETE REVIEWED AND APPROVED LOCALLY. SW SOFTWASH XT GANTRY <br /> CUSTOMER IS RESPONSIBLE FOR ALL PLUMBING, ELECTRICAL, CONCRETE, <br /> ANCHORS TO SECURE GANTRY TRACKS, GUIDE RAILS AND TREADLE PADS TK GANTRY TRACK 32 <br /> TO WASH BAY FLOOR AT A DEPTH OF 4", WITHOUT INTERFERING WITH AND ALL APPLICABLE INSPECTIONS, FEES, AND PERMITS AS REQUIRED BY UC UNDERCARRIAGE WASH MANIFOLD <br /> STEEL REINFORCEMENTS (REBAR) AND/OR FLOOR HEAT TUBING. AUTHORITY HAVING JURISDICTION (AHJ). <br /> 3) REFER TO SPECIFIC DETAIL SHEETS FOR INSTALLATION GUIDELINES. • DRAWINGS MAY NOT REFLECT FINAL EQUIPMENT LIST. PLEASE CHECK FINAL <br /> 4) SLOPE CONCRETE TOWARDS DRAIN: 1/8 " PER FOOT OR PER LOCAL CODE. ORDERS. <br /> THE INFORMATION CONTAINED IN THIS DOCUMENT IS DESIGNED AND DRAWING HISTORY PROPOSED DRAWINGS FOR: <br /> _y Mark V//® <br /> w °" PATE:11/ THORNTON CHEVRON , SOFTWASH XT w/FS-40D DRYER <br /> INTENDED FOR PRELIMINARY EDUCATION AND PLANNING PURPOSES ONLY. 01 INITIAL DRAWING RELEASE 11/12/15 JCH -°° <br /> THESE DRAWINGS IN NO WAY REPRESENT FINAL ARCHITECTURAL OR W lx0 uFL DRAWING NUMBER: DRAWN BY:6F C <br /> C€CkipA AoubirldMyof[L4uhTirA6 <br /> STRUCTURAL DRAWINGS OR PLANS. MARK VII EQUIPMENT IS NOT 02 UPDATED SHEET 8, RECLAIM 6/6/16 JCH <br /> RawN: Pilq-0 WJGE' AiE R: SHEET DESCRIPTION: REVISION: REF. DATE: SCALE:. SHEET: SIZE: MARK vu EQUIPMENT INC. <br /> RESPONSIBLE FOR THE ACTUAL RESULTS OF EFFORTS IMPLEMENTED DUE 03 ADDED NEW WAVE DIAGRAMS 8/12/16 JCH ARV DA CO 00 STREET tel: (303)423-4910 <br /> TO THE INFORMATION CONTAINED IN THIS DOCUMENT. NE oN. OFawU, LAI BAY AND EQUIPMENT LAYOUT 03 BL- 1511 - 15-03 J HAGAN 11/12/15 3/8"=1'-0 3 OF 7 D ARVADRC080003 (800) 525-8248 <br /> www.markvii.net fax: (303)430-0139 <br />