My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2300 - Underground Storage Tank Program
>
PR0535303
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 1:53:50 PM
Creation date
10/8/2018 4:25:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0535303
PE
2332
FACILITY_ID
FA0021137
FACILITY_NAME
OILSTOP
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
02
SITE_LOCATION
301 W KETTLEMAN LN
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED F <br />UNDERGROUND STORAGE TANK yy 0 <br />n <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) I` <br />TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections I, II, III, IV, and IX below) 430 <br />® 1. NEW PERMIT ❑ 3. RENEWAL PERMIT ❑ 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 5/27/2010 ',Ob <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />- <br />- <br />1 <br />4 <br />3 <br />1215 <br />1 <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) 3 <br />Prime Shine Express <br />BUSINESS SITE ADDRESS 103 <br />CITY 104 <br />301 W. Kettleman Ln. <br />Lodi, CA 95240 <br />II. TANK DESCRIPTION <br />TANK ID # 432 <br />TANK MANUFACTURER 433 <br />TANK CONFIGURATION: THIS TANK IS 434 <br />® 1. A STAND-ALONE TANK <br />❑ 2. ONE IN A COMPARTMENTED UNIT. <br />Complete one page for each compartment in the unit. <br />DATE US S STEM INSTALLED 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS IN THE UNIT 437 <br />480 <br />1 <br />III. TANK USE AND CONTENTS <br />TANK USE ❑ la. MOTOR VEHICLE FUELING ❑ lb. MARINA FUELING ❑ Ic. AVIATION FUELING 439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil) ❑ 5. EMERGENCY GENERATOR FUEL [HSC §25281.5(c)] <br />❑ 6. OTHER GENERATOR FUEL ❑ 95. UNKNOWN ® 99. OTHER (Specify): Oil 439a <br />CONTENTS PETROLEUM: ❑ la. REGULAR UNLEADED ❑ la MIDGRADE UNLEADED ❑ 1b. PREMIUM UNLEADED 440 <br />❑ 3. DIESEL ❑ 5. JET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ® 9. OTHER PETROLEUM (Specify): 10W-30 440a <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ 11. OTHER NON -PETROLEUM (Specify): 440b <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK ® 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 95. UNKNOWN 443 <br />PRIMARY CONTAINMENT ® 1. STEEL ❑ 3. FIBERGLASS ❑ 6. INTERNAL BLADDER 444 <br />❑ 7. STEEL+ INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 444a <br />SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED 445 <br />❑ 90. NONE ❑ 95. UNKNOWN ® 99. OTHER (Specify): Vault 445a <br />OVERFILL PREVENTION ❑ 1. AUDIBLE & VISUAL ALARMS ❑ 2. BALL FLOAT ❑ 3. FILL TUBE SHUT-OFF VALVE 452. <br />® 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT / WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION ® 1. SINGLE -WALLED ❑ 2. DOUBLE -WALLED ❑ 99. OTHER 460 <br />SYSTEM TYPE ❑ 1. PRESSURE ❑ 2. GRAVITY ® 3. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION [23 CCR §2636(a)(3)] 458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ® 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99.OTHER(Specify): 464a <br />SECONDARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ❑ 8. FLEXIBLE ❑ 10. RIGID PLASTIC 464b <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 464c <br />PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE 4644 <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT PRIMARY CONTAINMENT ❑ L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464e <br />464el <br />VENT SECONDARY CONTAINMENT ❑ L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464f <br />464£1 <br />VR PRIMARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4648 <br />464g I <br />VR SECONDARY CONTAINMENT ❑ L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464h <br />464h1 <br />VENT PIPING TRANSITION SUMP TYPE ❑ 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 90. NONE 464L <br />RISER PRIMARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464j <br />464' I <br />RISER SECONDARY CONTAINMENT ❑ L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 464k <br />464kl <br />FILL COMPONENTS INSTALLED ❑ 1. SPILL BUCKET ❑ 3. STRIKER PLATE/BOTTOM PROTECTOR ❑ 4. CONTAINMENT SUMP 45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE ❑ 1. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE 469a <br />CONSTRUCTION MATERIAL ❑ L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 99. OTHER (Specify) 4696-c <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT ❑ 6. ISOLATION 448. <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full compliance with legal requirements. <br />APPLICANT SIGNATURE <br />DATE 470 <br />APPLICANT NAME (print) 471. <br />APPLICANT TITLE 472_ <br />UPCF UST -B - 1/2 Rev. (12/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.