My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2300 - Underground Storage Tank Program
>
PR0535303
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2019 1:57:53 PM
Creation date
10/8/2018 4:26:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0535303
PE
2332
FACILITY_ID
FA0021137
FACILITY_NAME
OILSTOP
STREET_NUMBER
301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
02
SITE_LOCATION
301 W KETTLEMAN LN
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMEN', <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Prime Shine Express <br />Inspection date: <br />5/27/2010 <br />Facility address: <br />301 W. Kettleman Ln. Lodi, Ca 95240 <br />UST # / <br />Product <br />1 <br />IOW -30 <br />2 <br />15W-40 <br />3 <br />'5W-40 <br />Facility contact: Title: Phone: <br />Peter Kroeze Manager 368-9777 <br />4 <br />'5W-20 <br />5 <br />-1 OW -30 <br />6 <br />ATF <br />7 <br />1OW-30 <br />Monitoring panel: <br />Piping system: <br />❑ Pressurized ® Suction ❑ Gravity <br />Overfill prevention: <br />❑ Mechanical <br />® Audible/visual <br />Violations: <br />ElM1-RDetect ElM3-BothTank#K75-90,#9hwoil <br />❑ M2-RPrev <br />Inspection type: <br />® Routine ❑ Monitoring Certification ❑ Installation ❑ Other <br />Designated operator: ICC exp. date: <br />On site Service Technician's name: ICC exp. date: <br />Manufacturer's training: <br /># <br />Code Section <br />VIOONS <br />V <br />V <br />HSC=CA Health & SafetyCode; CCR=CAC Code of Regulations; V=Violation; RV=Re eat Violation <br />1 <br />HSC 25284 <br />No permit to operate <br />2 <br />CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test <br />notification not provided to the Environmental Health Department (EHD) at least 48 hours prior to <br />conducting the test <br />3 <br />CCR 2711(b) & (c) <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />4 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the EHD <br />5 <br />CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />6 1 <br />CCR 2712(i) <br />Monitoring and/or response plan is not onsite <br />7 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 (M1) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1) date and time of <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations <br />8 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre -January 1, 1984) not performed (M1) <br />9 <br />HSC 25292.1 <br />UST s stem is not operated to prevent unauthorized release, including spills and overfills <br />10 <br />CCR 2632(c)(2) <br />Monitoring system is not present in the interstitials ace of a double walled UST/piping (M7) <br />11 <br />CCR 2630(d) <br />UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportune (Mi) <br />12 <br />HSC 25291(b) <br />UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br />containment <br />13 <br />CCR 2636(f)(1) <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (M1) <br />an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />14 <br />CCR 2631(a) <br />Primary containment is not product tight <br />15 <br />HSC 25291(a)(2) <br />Secondary containment for UST system is not tight <br />16 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />17 <br />CCR 2636(f)(2) <br />Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (M1) <br />18 <br />CCR 2635(b)(1) <br />Spill container not installed, failed to contain a minimum capacity of five gallons, or failed to (M2) <br />provide a means to keep the spill container empty <br />19 <br />CCR 2635(b) 2 <br />Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br />20 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br />21 <br />HSC 25291(e) <br />Water in 20 containment not removed, analyzed & properly disposed of <br />22 <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight (M1) <br />hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) <br />Failed to inform the EHD of a c e f designated operator within 30 days <br />23b <br />I CCR 2715(b) <br />I Designated operator did no ossess current ICC UST System Operator certification <br />EHD inspector. <br />C t <br />R rved by: <br />u-;)- <br />Titre: <br />EHD 23-02-002 REV 04/08/10 Page 1 UST UFFIGIAL INSPt(; I IUN KLPUK I <br />
The URL can be used to link to this page
Your browser does not support the video tag.