My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0003025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
301
>
2900 - Site Mitigation Program
>
PR0508132
>
ARCHIVED REPORTS XR0003025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2018 9:11:06 AM
Creation date
10/9/2018 2:10:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS XR0003025
FileName_PostFix
XR0003025
RECORD_ID
PR0508132
PE
2957
FACILITY_ID
FA0007953
FACILITY_NAME
CHEVRON #9-5775
STREET_NUMBER
301
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04514002
CURRENT_STATUS
01
SITE_LOCATION
301 KETTLEMAN LN
P_DISTRICT
004
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
246
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
u + Lancaster Laboratories <br />2425 New Holland Pike 0 Lancaster, PA 17601 Explanation of Symbols and Abbreviations <br />The following defines common symbols and abbreviations used in reporting technical data: <br />ND d <br />f^ <br />TNTC <br />none etected <br />Too Numerous To Count <br />BIVIQL <br />MPN <br />Below Minimum Quantitation Level <br />' <br />IU <br />International Units <br />CP Units <br />Most Probable Number <br />cobaft-chloroplatinate units <br />umhoslcm <br />micromhos/cm <br />MTU <br />nephelometric turbidity units <br />C <br />degrees Celsius <br />F <br />degrees Fahrenheit <br />meq <br />milliequivalents <br />Ib. <br />pound(s) <br />g <br />gram(s) <br />kg <br />kilogram(s) <br />ug <br />microgram(s) <br />mg <br />milligram(s) <br />ml <br />m3 <br />milliliter(s) <br />cubic meter(s) <br />I <br />liter(s) <br />ul <br />microliter(s) <br />< <br />less than - The number following the sign is <br />the limit of tluantitation, <br />the smallest amount of analyte which can be <br />F <br />reliably determined using this specific test. <br />' <br />> <br />greater than <br />J <br />estimated value — The result falls within the Method Detection Limit (MDL) and Limit of Quantitation (LOQ). <br />ppm parts per million - One ppm is equivalent to one milligram per kilogram (mg/kg), or one gram per million grams. For <br />aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter (mg/]),because one liter of water has a <br />weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter of gas per liter of gas, <br />ppb parts per billion <br />Dry weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight <br />basis concentration to approximate the value present in a similar sample without moisture. All other results are reported <br />on an as -received basis. <br />U.S. EPA CLP Data Qualifiers: <br />Organic Qualifiers Inorganic Qualifiiers <br /># A TIC is a possible aldol -condensation product B Value is <CRDL, but ?IDL <br />B Analyte was also detected in the blank E Estimated due to interference <br />C Pesticide result confirmed by GCIMS M Duplicate injection precision not met <br />D Compound quantitated on a diluted sample N Spike sample not within control limits <br />E Concentration exceeds the calibration range of S Method of standard additions (MSA) used <br />the instrument for calculation <br />N Presumptive evidence of a compound (TICS only) U Compound was not detected <br />E P Concentration difference between primary and W Post digestion spike out of control limits <br />?-° confirmation columns X25% _ Duplicate analysis not within control limits <br />U Compound was not detected + Correlation coefficient for MSA <0.995 <br />�- X,Y,Z Defined in case narrative <br />:... Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br />otherwise noted under the individual analysis. <br />Measurement uncertainty values, as applicable, are available upon request. <br />' Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological - <br />analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the <br />test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact <br />us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br />staff. This report shall not be reproduced except in full, without the written approval of the laboratory. <br />WARRANTY AND LIMITS OF LIABILITY - In accepting analytical work, we warrant the accuracy of test results for the sample as submitted. <br />THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br />-- IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br />PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br />�- FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br />OF PROFIT OR GOODWILL REGARDLESS OF (A) THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF LANCASTER <br />to—,LABORATORIES AND (B) WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH <br />DAMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order <br />'---'for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br />Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. <br />3758.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.