. SVEIGWE SYSTEM <br />FIELD MONITORING DATA SHEETS <br />Date: Time of Arrival: <br />Technician: Steve Thompson Time of Departure: <br />Site Engineer: David M. Evans Was Site Engineer contacted from field? Yes No <br />PART A: GENERAL INFORMATION <br />Site Location: Chevron 95775 301 West Ketileman Lane Lodi CA Project No. 077.43452.550 <br />Abatement Equip.: Falmouth Products Falco 100 Catalytic Oxidizer <br />SVE Slower: 5 hp motor, 15.5 Am <br />Telemetry: -I<"' '/ p p <br />Electrical Power: 230 V 3 phase — 2DO am <br />Supplemental Fuel: None <br />No. of IVO barrels at site: Full Empty <br />PART t3- SVE SYSTEM DATA <br />r: <br />i) <br />It) <br />System up or down upon arrival: <br />Hourmeter Reading: d d <br />Serial No.: <br />Max AMP Rating.: S <br />MAX AMP Rating: <br />Elect, Meter Reading: <br />(If down please complete PART E) <br />At time: —7. .,-- � --; <br />Flow Data <br />Before Adjustment <br />After Adjustment <br />Final <br />% Dilution air valve 9E2n <br />u�S <br />% Recirculation valve oppen <br />WO Content I <br />�1 <br />— <br />Vacuum @ blower (in H2O) <br />Gauge Ran <br />ZJ Z-1 <br />AMPS drawn by blower motor AMPS <br />f <br />Total System Flow (A P, in HZO) <br />Pipe Sizef. ` <br />.�9 <br />9 3-;;; <br />Well Field Air Flaw (A P. in H2O) <br />PiDe Size 6 4" <br />c� <br />Dilution Air Flow (A P, 'H20) <br />Pipe Size 40" <br />FID Data <br />W/ Carbon <br />W/O Carbon <br />Difference <br />System Influent v before dilution <br />ffj <br />System Influent my after dilution <br />System Effluent v <br />— <br />Field Instrument Used: rz 2. Last Calibrated: A ? <br />