Laserfiche WebLink
Date <br />Technician <br />Site Engineer <br />PART A GENERAL INFORMATION <br />SVEIGWE SYSTEM <br />FIELD MONITORING DATA SHEETS <br />Time of Arrival <br />Time of Departure <br />Was Site Engineer contacted from fields Yes <br />Site Locatmn Chevron 9-5775 301 West Kettleman Lane Lodi CA <br />Abatement Equip Falmouth Products Falco 100 Catalytic Oxidizer <br />SVE Slower 5 ho motor, 15 5 Am <br />Telemetry <br />Electrical Power 230 V 3 phase — 200 amp <br />Supplemental Fuel None <br />No of K/O barrels at site Full Empty <br />PART B SVE SYSTEM DATA <br />System up or down upon arrival <br />Hourmeter Reading <br />Protect No 077 41991 043 <br />Serial No <br />Max AMP Rating <br />MAX AMP Rating <br />Elect Meter Reading <br />(If down please complete PART E) <br />At time <br />No <br />Flow Data <br />Before Adjustment <br />After Adjustment <br />Final <br />% Dilution air valve open <br />% Recirculation valve open <br />KIO Content al <br />Vacuum Q blower (in H2O) <br />Gauge Range <br />AMPS drawn by blower motor AMPS <br />Total System Flow (A P, in H20) <br />Pipe Sue " <br />Well Field Air Flow (A P, in H2O) <br />Pipe Size 0 4" <br />Dilution Air Flow (A P "H20) <br />PiDe Size 6" <br />FID Data <br />WI Carbon <br />W/O Carbon <br />Difference <br />System Influent my before dilution <br />System Influent my after dilution <br />System Effluent my <br />Field Instrument Used Last Calibrated <br />