Laserfiche WebLink
Lancaster Laboratories <br />Where quality is a Science. <br />Lancaster Laboratories Sample No. WW 3733546 <br />Collected:11/20/2001 09:07 by DM <br />Submitted: 11/27/2001 10:00 <br />Reported: 12/11/2001 at 17:45 <br />Discard: 01/11/2002 <br />MW -7B -W-011120 NA Water <br />Facility# 95775 Prj.# 077.43449.650 SIRC <br />301 W. Kettleman Ln Lodi 70607700839 MW -7B <br />7B --- <br />Account Number: 10869 <br />Chevron Products Company <br />6001 Bollinger Canyon Rd <br />Building L, PO Bax 6004 <br />San Ramon CA 94583-0904 <br />As Received <br />CAT As Received Method <br />No_ Analysis Name CAS Number Result Detection <br />Limit <br />01412 <br />Methanol and Ethanol <br />Methanol (by Direct Injection) <br />67-56-1 <br />N.D. <br />200. <br />401414 <br />1729 <br />TPH-GRO - Waters <br />01730 <br />TPH-GRO - Waters <br />n.a. <br />N.D. <br />50. <br />The reported concentration of TPH-GRO <br />does not <br />include MTBE or <br />other <br />gasoline constituents eluting prior <br />to the C6 <br />(n -hexane) TPH-GAO range <br />start time. <br />02159 <br />BTEX, MTBE <br />02161 <br />Benzene <br />71-43-2 <br />N.D. <br />0.50 <br />02164 <br />Toluene <br />108-88-3 <br />N.D. <br />0.50 <br />02166 <br />Ethylbenzene <br />100-41-4 <br />N.D. <br />0.50 <br />02171 <br />Total Xylenes <br />1330-20-7 <br />N.D. <br />1.5 <br />01594 <br />BTEX + Oxygenates by 8260B <br />01587 <br />Ethanol <br />64-17-5 <br />N.D. <br />50. <br />02010 <br />Methyl t -butyl ether <br />1634-04-4 <br />N.D. <br />0.5 <br />02011 <br />di -Isopropyl ether <br />108-20-3 <br />N.D. <br />0.5 <br />02013 <br />Ethyl t -butyl ether <br />4537-92-3 <br />N.D. <br />0.5 <br />02014 <br />t -Amyl methyl ether <br />994-05-8 <br />N.D. <br />0.5 <br />02015 <br />t -Butyl alcohol <br />75-65-0 <br />N.D. <br />5. <br />05402 <br />1,2-Dichloroethane <br />107-06-2 <br />N.D. <br />0.5 <br />05412 <br />1,2-Dibromoethane <br />106-93-4 <br />N.D. <br />0.5 <br />The vial submitted for volatile <br />analysis did <br />not have a pH < 2 <br />at the time <br />of analysis. Due to the volatile nature of <br />the analytes, it is <br />not <br />appropriate for the laboratory <br />to adjust the <br />pH at the time of <br />sample <br />receipt. The pH of this sample <br />was pH = 5. <br />Page i of 2 <br />Dilution <br />Units Factor <br />ug/l 1 <br />ug/l <br />ug/l <br />ug/l <br />ug/l <br />ug/l <br />ug/1 <br />ug/l <br />ug/1 <br />ug/1 <br />ug/1 <br />ug/l <br />ug/l <br />ug/l <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />Z <br />Lancaster Laboratories, Inc. <br />ME M 13E R 2425 New Holland Pike <br />®PO Box 12425 <br />Lancaster, PA 17605.2425 <br />717-656-2300 Fax: 717-656-2681 2216 Rev. 9/11100 <br />