My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
16900
>
2800 - Aboveground Petroleum Storage Program
>
PR0528139
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2019 9:58:34 AM
Creation date
10/10/2018 10:45:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528139
PE
2832
FACILITY_ID
FA0007697
FACILITY_NAME
SAFEWAY DISTRIBUTION CENTER
STREET_NUMBER
16900
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20943001
CURRENT_STATUS
01
SITE_LOCATION
16900 W SCHULTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY DISTRIBUTION CENTER 16900 W SCHULTE RD,TRACY September 24, 2018 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25270.6(a)Failed to file HMBP or annual facility tank statement. <br /> A tank facility statement or business plan has not been submitted.A tank facility statement identifying the name and <br /> address of the tank facility, a contact person for the tank facility,the total storage capacity of the tank facility, and the <br /> location, size, age, and contents of each storage tank that exceeds 10,000 gallons in capacity and that holds a <br /> substance containing at least 5 percent of petroleum shall be submitted annually. Submittal of a business plan <br /> satisfies the requirement to submit a tank facility statement. Immediately submit a tank facility statement or <br /> business plan. <br /> Note: <br /> To meet the requirement by submitting a business plan, you must submit the Facility Information, Hazardous <br /> Materials Inventory, Site Map and Emergency Response and Training Plans submittal elements through CERS.To <br /> indicate that you are using your business plan to meet the APSA reporting requirement, select the Provided <br /> Elsewhere in CERS document option, select Hazardous Materials Inventory, then click the Save button. <br /> This is a Class II violation. <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> The SPCC plan calls for a maximum of six 55 gallon drums in the"perishables"warehouse, a total of 7 drums <br /> where observed in the warehouse, including one used oil drum. Spill pallets are being used to capture diesel that <br /> may escape from the hoses during the loading of the three 12,000 gallon diesel tanks,this procedure is not <br /> described in the SPCC plan.The Spill Prevention, Control, and Countermeasure (SPCC) Plan must be amended <br /> when there is a change in the facility design, construction, operation, or maintenance that materially affects its <br /> potential for a discharge,within 6 months of the change, and implemented as soon as possible, not later than 6 <br /> months following preparation of the amendment. Immediately make all necessary amendments to the SPCC Plan <br /> to accurately represent the procedures and policies currently in place at the facility. <br /> Note: Two new containers with a capacity of over 55 gallons of new oil were observed in the room that contains the <br /> 4,800 gallon new oil container and the 1,000 gallon used oil container.The new containers were not addressed in <br /> the plan, but it was stated that they have been on the property for less that six months. Used oil containers of 55 <br /> gallons were observed outside the truck shop,this storage area was not described in the SPCC plan. It was stated <br /> that the 55 gallon drums were recently moved there while cleaning the facility. <br /> This is a minor violation. <br /> FA0007697 PR0528139 SCO01 09/24/2018 <br /> EHD 28-01 Rev.09/10/2018 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.