Laserfiche WebLink
AMERICAN ENVIRONMENTAL NETWORK 11 East Olive Rd Pensacola, FL 32514 (850)474-1001 <br /> Data Qualifiers for Final Report <br /> � <br /> EN-Pensacola In r anic/ r anic <br /> Adjusted reporting limit due to sample matrix(dilution prior to digestion and/or analysts) <br /> t Elevated reporting limit due to dilution into calibration range <br /> * Elevated reporting limit due to matrix interference(dilution prior to digestion and/or analysts) <br /> Elc%ated reporting limit due to insufficient sample size <br /> D Diluted out <br /> J5 The reported .alue is quantitated as a TIC,therefore, it is estimated <br /> ND=Not Detected N/S=Not Submitted N/A=Not Applicable <br /> Florida Pro ect Inorganic/Organic <br /> Y1 Improper preservation,no preservative present in sample upon receipt <br /> Y2 Improper preservation,incorrect preservative present in sample upon receipt <br /> Y3 Improper preservation,sample temperature exceeded EPA temperature limits of 2-6°C upon receipt <br /> Y(FL description) The laboratory analysts was from an unpreserved or improperly preserved sample The data may not be accurate <br /> Q Sample held beyond the accepted holding time <br /> I The reported value is<Laboratory RL and>laboratory MDL <br /> U The reported value is:�Laboratory MDL(value for sample result is reported as the MDL) <br /> U(FL description) Indicates the compound was analyzed for but not detected <br /> T The reported value is<Laboratory MDL(value shall not be used for statistical analysis) <br /> V The analyte was detected in both the sample and the associated method blank _ <br /> J1 Surrogate recovery limits have been exceeded <br /> J2 The sample matrix interfered with the ability to make any accurate determinations <br /> J3 The reported value failed to meet the established quality control criteria for either precision or accuracy <br /> J(FL description) Estimated value,not accurate <br /> AFCEE Protects(under .APP)and All Other(AEN-PN) lects/Sites for Inorganic/Organir Parameters <br /> J4 (For positive results) Temperature limits exceeded(<2°C or>6°C) <br /> J(AFCEE description) The anaiyte was positively identified,the quantitation is an estimation <br /> (For nondetects) Temperature limits exceeded(:�2°C or>6°C) <br /> Improper preservation,no preservative present in sample upon receipt <br /> Improper preservation,incorrect preservative present in sample upon receipt <br /> R4 Holding time exceeded <br /> R5 Collection requirements not met,improper container used for sample <br /> R(AFCEE description) The data are unusable due to deficiencies in the ability to analyze the sample and meet QC criteria <br /> F <RL and>laboratory MDL <br /> F(AFCEE desenption) The analyte was positively identified but the associated numerical value is below the AFCEE or lab RL <br /> U2 <Laboratory MDL(value for result will be the MDL,never below the MDL) <br /> U(AFCEE description) The analyte was analyzed for but not detected The associated numerical value is at or below the MDL <br /> B(AFCEE description) The analyte was found in the associated blank,as well as in the sample <br /> IlQR Projects Inorg rna c/Organtc / / - <br /> A Acceptable <br /> R6 Rejected 4( <br /> Examples ICR Flags <br /> R6=Laboratory extracted the sample but the refrigerator malfunctioned so the extract became warm and client was notified <br /> R6=Sample arrived in laboratory in good condition,however,the laboratory did not analyze it within EPA's established holding time limit <br /> CLP and CLP-like Projects <br /> Refer to referenced CLP Statement of Work(SOW)for explanation of data qualifiers <br /> IDL=Laboratory Instrument Detection Limit <br /> MDL=Laboratory Method Detection Limit <br /> RL=Reporting Limit(AFCEE RLs are listed in the AFCEE QAPP) <br /> CLP CRDL=CLP Contract Required Detection Limit(these limits are listed in the EPA CLP Statement of Work or SOW) <br /> CLP CRQL=CLP Contract Required Quantitation Limit(these limits are listed in the EPA CLP Statement of Work or SOW) <br /> -Any time a sample arrives at the laboratory improperly preserved(at improper pH or temperature)or after holding time has expired or prepared or <br /> lyzed after holding time,client must be notified in writing(i a case narrative) <br /> AEN-Pensacola uses the most current promulgated methods contained in the reference manuals <br /> wordlton ,nagslksh revised 10133/47 <br />