My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0005572
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2900 - Site Mitigation Program
>
PR0541478
>
ARCHIVED REPORTS XR0005572
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 3:25:40 AM
Creation date
10/10/2018 11:24:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS XR0005572
FileName_PostFix
XR0005572
RECORD_ID
PR0541478
PE
2950
FACILITY_ID
FA0023778
FACILITY_NAME
CHEVRON STATION #210997
STREET_NUMBER
1442
Direction
W
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 W COLONY RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMERICAN ENVIRONMENTAL NETWORK 11 East Olive Road Pensacola, Florida 32514 (850) 474-1001 <br /> [0) Page 2 <br /> Date 09-Jun-98 <br /> ----- <br /> N/A = NOT APPLICABLE ----- Common Footnotes WetChem <br /> NIS = NOT SUBMITTED <br /> NIC = SAMPLE AND DUPLICATE RESULTS ARE AT OR BELOW AEN REPORTING LIMIT, <br /> THEREFORE, THE RPD IS "NOT CALCULABLE" AND NO CONTROL LIMITS APPLY <br /> N/D = NOT DETECTED <br /> R = REACTIVE <br /> T = TOTAL <br /> G = SAMPLE AND/OR DUPLICATE RESULT IS BELOW 5 X AEN REPORTING LIMIT AND <br /> THE ABSOLUTE DIFFERENCE BETWEEN THE SAMPLE AND DUPLICATE RESULT IS AT <br /> OR BELOW AEN REPORTING LIMIT, THEREFORE, THE RESULTS ARE "IN CONTROL" <br /> Q = THE ANALYTICAL (POST-DISTILLATION) SPIKE IS REPORTED DUE TO PERCENT RECOVERY <br /> BEING OUTSIDE ACCEPTANCE LIMITS ON THE MATRIX (PRE-DISTILLATION) SPIKE <br /> # = ELEVATED REPORTING LIMIT DUE TO INSUFFICIENT SAMPLE <br /> + = ELEVATED REPORTING LIMIT DUE TO DILUTION INTO CALIBRATION RANGE <br /> * = ELEVATED REPORTING LIMIT DUE TO MATRIX INTERFERENCE (DILUTION PRIOR DIGESTION <br /> AND/OR ANALYSIS) <br /> Q = ADJUSTED REPORTING LIMIT DUE TO SAMPLE MATRIX (DILUTION PRIOR TO DIGESTION <br /> AND/OR ANALYSIS) <br /> P = ANALYTICAL (POST DIGESTION) SPIKE <br /> I = DUPLICATE INJECTION <br /> & = AUTOMATED <br /> F = SAMPLE SPIKED > 4 X SPIKE CONCENTRATION <br /> N/C+ = NOT CALCULABLE <br /> H = SAMPLE AND/OR DUPLICATE RESULT IS BELOW 5 X AEN REPORTING LIMIT AND THE <br /> ABSOLUTE DIFFERENCE BETWEEN THE RESULTS EXCEEDS THE AEN REPORTING <br /> LIMIT, THEREFORE, THE RESULTS ARE "OUT OF CONTROL" <br /> A = SAMPLE AND DUPLICATE RESULTS ARE "OUT OF CONTROL" <br /> Z = THE SAMPLE RESULT FOR THE SPIKE IS BELOW THE REPORTING LIMIT HOWEVER, <br /> THIS RESULT IS REPORTED FOR ACCURATE QC CALCULATIONS <br /> NH= SAMPLE AND / OR DUPLICATE RESULT IS BELOW 5 X AEN REPORTING LIMIT <br /> AND THE ABSOLUTE DIFFERENCE BETWEEN THE RESULTS EXCEEDS THE AEN <br /> . REPORTING LIMIT, THEREFORE, THE RESULTS ARE "OUT OF CONTROL" <br /> SAMPLE IS NON-HOMOGENEOUS <br /> (*} = REPORTING LIMITS RAISED DUE TO CLP METHOD NOT REQUIRING A CONCENTRATION STEP FOR CN <br /> (CA) = SEE CORRECTIVE ACTIONS FORM <br /> **= MATRIX INTERFERENCE <br /> SW-846, 3rd Edition, latest EPA-approved edition <br /> EPA 600/4-79-020, Revised March 1983 <br /> STANDARD METHODS, For the Examination of Water and Wastewater, latest EPA-approved edition <br /> NIOSH Manual of Analytical Methods, 4th Edition <br /> ANNUAL BOOK OF ASTM STANDARDS, VOLUMES 11 01 and 11 02, latest EPA-approved edition <br /> METHODS FOR THE DETERMINATION OF INORGANIC SUBSTANCES IN ENVIRONMENTAL SAMPLES, <br /> EPA600/R-93/100, AUGUST 1993 <br /> METHODS FOR SOIL ANALYSIS, PART 2, CHEMICAL AND MICROBILOGICAL PROPERTIES, 2ND EDITION <br /> AEN-PN USES THE MOST CURRENT PROMULGATED METHODS FROM THE REFERENCES LISTED ABOVE <br /> 1 COLIFORM COLIFORM PRECISION IS MEASURED BY THE ABSOLUTE DIFFERENCE BETWEEN <br /> THE LOGARITHM OF COLONIES PER 100 MLS OF SAMPLE ON DUPLICATE PLATES <br /> 2 PH PH PRECISION IS MEASURED BY THE ABSOLUTE DIFFERENCE BETWEEN THE <br /> SAMPLE AND DUPLICATE ANALYSIS <br /> 3 FLASHPOINT FLASHPOINT PRECISION IS MEASURED BY THE ABSOLUTE DIFFERENCE BETWEEN <br /> THE SAMPLE AND DUPLICATE ANALYSIS <br /> RFD = RELATIVE PERCENT DIFFERENCE (OR DEVIATION) <br /> RPT LMTS = REPORTING LIMITS BASED ON METHOD DETECTION LIMIT STUDIES <br /> DPH = DOLLY P HWANG RB = REBECCA BROWN WH = WENDY HAGGARD <br /> ED = ESTHER DANTIN CR W CYNTHIA ROBERTS AB = AMY BRADLEY <br /> BE = BETTY EVERTON PLD = PAULA L DOUGHTY JTZ = JONATHAN T ZIENTARSKI <br /> RH = RICKY HAGENDORFER <br /> 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.