Laserfiche WebLink
San Joaquin County utu <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />CHEVRON PRODUCTS COMPANY #1001621 <br />22888 S KASSON RD, TRACY <br />January 14, 2016 <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />723 <br />CFR 112.8(d)(1) <br />Failed to provide corrosion protection for buried piping <br />❑ V R u COS <br />724 <br />CFR 112.8(d)(2) <br />Failed to cap/blank-flange connection at transfer point and mark its origin if not in service <br />❑ V ❑ R ❑ COS <br />725 <br />CFR 112.8(d)(3) <br />Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction <br />❑ V ❑ R ❑ COS <br />726 <br />CFR 112.8(d)(4) <br />Failed to regularly inspect aboveground valves, piping, and appurtenances <br />❑ V ❑ R ❑ COS <br />727 <br />CFR 112.8(d)(4) <br />Failed to conduct integrity and leak test on buried piping any time it is worked on <br />❑ V ❑ R ❑ COS <br />728 <br />CFR 112 8(d)(5) <br />Failed to adequately warn vehicles entering facility to protect piping and other transfer operations <br />V 1 R COS <br />Other Violations <br />4010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />4020 <br />See below <br />Unlisted Training violation <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />4030 <br />See below <br />❑ V ❑ R ❑ COS <br />4040 <br />See below <br />Unlisted Release/Leaks/Spills violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />604 <br />CFR 112.7(a)(3) No facility diagram or didn't show location and contents of containers, transfer stations, and pipes. <br />The facility diagram did not indicate the contents of each fixed storage container. The Spill Prevention, Control, and <br />Countermeasure (SPCC) Plan shall include a facility diagram which must mark the location and contents of each <br />fixed storage container and the storage area where mobile or portable containers are located. It must identify the <br />location of and mark as "exempt" underground tanks. It must also include all transfer stations and connecting <br />pipes, including intra -facility gathering lines. Immediately update the facility diagram to include all of the required <br />information. Submit a legible copy of the updated facility diagram to the EHD for review. <br />This is a Class II violation. <br />609 <br />CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge. <br />Multiple cracks were found in the concrete secondary containment dike along the northern part of the facility north of <br />the fire access road. It appears that some have been attempted on the cracks, but not all the cracks have evidence <br />of repair attempts being conducted. It appears the local wildlife have also been burrowing into the dirt below the <br />concrete secondary containment dike. Settling of the soil at the base of the northern section of secondary <br />containment dike was observed on the facility side of the concrete secondary containment dike. It appears that the <br />integrity of the concrete secondary containment dike is compromised and may no longer be adequate to prevent a <br />discharge. A facility shall provide appropriate containment and/or diversionary structures or equipment to prevent a <br />discharge. The entire containment system, including walls and floor, must be capable of containing oil and must be <br />constructed so that any discharge from a primary containment system will not escape the containment system <br />before cleanup occurs. Immediately provide adequate secondary containment for all aboveground petroleum <br />storage containers larger than 55 gallons. <br />This is a Class II violation. <br />Received <br />(initial): 41w � ;a, 14V1 <br />Inspector: <br />ARIS VELOSO, Senior REHS <br />Phone: <br />(209) 468-3453 <br />Date: <br />01/14/2016 <br />Page 3of6 <br />