My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
833
>
2800 - Aboveground Petroleum Storage Program
>
PR0529406
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2019 8:44:08 AM
Creation date
10/11/2018 1:40:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0529406
PE
2833
FACILITY_ID
FA0002818
FACILITY_NAME
UNION PACIFIC RAILROAD - STOCKTON
STREET_NUMBER
833
Direction
E
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
08801001
CURRENT_STATUS
01
SITE_LOCATION
833 E EIGHTH ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aJOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.smgov.org/ehd <br /> CONTINUATION FORM Page: 7 of 7 <br /> OFFICIAL INSPECTION REPORT Date: 08/20/12 <br /> Facility Address: 833 E. Eighth St., Stockton Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> 611. Liquid level sensing devices are not installed and regularly tested on all of the containers. The <br /> 88,000 gallon waste water tank (TNKS-0056) was observed with a broken gauge. You must install at <br /> least one of the following devices in each container: <br /> - High liquid level alarm with audible or visual signal <br /> - High liquid level pump cutoff device set to stop flow at a predetermined content level <br /> - Direct audible or code signal communication between the container gauger and the pumping station <br /> - Fast response system, such as digital computer, telepulse, or direct vision gauge. If a direct vision <br /> gauge is being used for determining the liquid level of each tank, a person must be present to <br /> monitor gauges and the overall filling of the tanks. <br /> Immediately install approved liquid level sensing devices on all APSA regulated containers, in <br /> accordance with 40 CFR 112.8, and implement necessary procedures to ensure that the devices are <br /> fully functional and in use at all times during tank filling operations. <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by September 22, <br /> 2012, along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> Note: Several out-of-service tanks and containers on site are labeled "empty." In order to be excluded <br /> from SPCC Plan requirements, these containers must be all of the following requirements: <br /> (1) All liquid and sludge has been removed from each container and connecting line <br /> (2) All connecting lines and piping have been disconnected from the container and blanked off <br /> (3) All valves (except for ventilation valves) have been closed and locked <br /> (4) Conspicuous signs have been posted on each container stating that it is a permanently closed <br /> container and noting the date of closure <br /> Note: This facility is currently in the process of having all of their SPCC Plans updated to bring them into <br /> compliance with current regulations. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> Stacy Rivera (209) 468-3440 <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.