Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
833
>
2800 - Aboveground Petroleum Storage Program
>
PR0529406
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2019 8:44:08 AM
Creation date
10/11/2018 1:40:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0529406
PE
2833
FACILITY_ID
FA0002818
FACILITY_NAME
UNION PACIFIC RAILROAD - STOCKTON
STREET_NUMBER
833
Direction
E
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
08801001
CURRENT_STATUS
01
SITE_LOCATION
833 E EIGHTH ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> UNION PACIFIC RAILROAD- Stockton 833 E EIGHTH ST. STOCKTON January 12, 2016 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V n R n COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 HSC 25270.4.5(a) Failed to properly close a tank that is considered permanently closed. <br /> Tank numbers TNKO-0296 and TNKO-0297 are not in use, but have not been properly labeled as permanently <br /> closed. When a tank is not in use, it must be permanently closed by meeting the following conditions: <br /> - remove all liquid and sludge from each container and connecting line <br /> -disconnect and blank off all connecting lines and piping have from the tank <br /> -close and lock all valves <br /> - post a sign conspicuously stating that it is a permanently closed container and denoting the date of closure. <br /> Immediately "Permanently Close"all tanks that are not being used or amend the Spill Prevention, Control, and <br /> Countermeasure Plan to include all petroleum tanks that have not been permanently closed. <br /> This is a Class II violation. <br /> 201 CFR 112.3(d) Plan certification by a Professional Engineer(PE) missing or incomplete. <br /> The Professional Engineer (PE) certification is incomplete. The SPCC plan certification was dependant on <br /> completion of amendments, including replacing damaged tank gauges and installing secondary containment. The <br /> PE certification must include all of the aspects in 40 CFR 112.3(d)(1), including attesting that the PE is familiar with <br /> 40 CFR Part 112, he or his agent has visited and examined the facility, the Spill Prevention, Control, and <br /> Countermeasure (SPCC) Plan has been prepared in accordance with good engineering practice, including <br /> consideration of applicable industry standards, procedures have been established for required inspections and <br /> testing, and the Plan is adequate for the facility. Immediately obtain a complete PE certification for the facility's <br /> SPCC Plan. Submit a copy of the completed certification to the EHD. <br /> This is a repeat violation, Class II. <br /> Received by spector: Phone: Date: <br /> (initial)-.-. STACY RIVERA, Senior REHS (209) 468-3440 01/12/2016 <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.