Laserfiche WebLink
INDIVIDUA., ANK/LINE/LEAK DETECTOR TE REPORT <br />TEST DATE: 04/09/98 WORK ORDER NUMBER: 2204184 <br />CLIENT: CHEVRON USA SITE: CHEVRON #95775 <br />TANK TEST RESULTS Test Method: VacuTect <br />TANK INFORMATION <br />End (in) <br />Dipped Water Level: 0.00 <br />Tank ID: 10K 2 <br />Material: FIBERGLASS <br />Bottom to top fill in inches: <br />125.0 <br />Product: REG UNLEAD <br />Tank manifolded: NO <br />Bottom to grade fill in inches: <br />130.0 <br />Capacity in gallons: 9,728 <br />Vent manifolded: No <br />Fill pipe length in inches: <br />34.0 <br />Diameter in inches: 91.00 <br />Vapor recovery manifolded. NO <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 350 <br />Impact Valves Operational: N <br />Stage I vapor recovery: <br />DUAL <br />Tank age (years): <br />Overfill protection: NO <br />Stage II vapor recovery: <br />BALANCE <br />Fuel pure rating: <br />Overspill protection: NO <br />Installed: <br />10 <br />CP installed on: / <br />/ <br />30 <br />30 <br />COMMENTS <br />30 <br />Test 1: Start time: <br />20:03 <br />TANK TEST RESULTS Test Method: VacuTect <br />tart (in) <br />End (in) <br />Dipped Water Level: 0.00 <br />0.00 <br />Dipped Product Level: 65.00 <br />65.00 <br />Probe Water Level: 0.000 <br />0.000 <br />Ingress Detected: Water N Bubble <br />N UllageN <br />Test time: <br />20:45-21:45 <br />VacuTect Test Type: <br />Single tank <br />VacuTect Probe Entry Point: <br />Fill <br />Pressure Set Point: <br />-1.00 <br />Tank water level in inches: <br />0.00 <br />Water table depth in inches: <br />141.00 <br />Determined by (method): <br />MONTR WELL <br />Result: <br />PASS <br />COMMENTS <br />MAG PROBE::: MW BOTTOM <br />LEAK DETECTOR RESULTS Test method: <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />Make: <br />Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliancy cc: <br />Test leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />COMMENTS <br />LINE TEST RESULTS <br />I est type: TLD -1 <br />LINE <br />A <br />8 <br />C <br />D <br />Material: <br />SW FIBERG <br />SW FIBERG SW FIBERG <br />SW FIBERG <br />Diameter (in): <br />2.0 <br />2.0 <br />2.0 <br />2.0 <br />Length (ft): <br />40.0 <br />40.0 <br />40.0 <br />40.0 <br />Test psi: <br />15 <br />15 <br />15 <br />15 <br />Bleedback cc: <br />10 <br />10 <br />10 <br />10 <br />Test time (min): <br />30 <br />30 <br />30 <br />30 <br />Test 1: Start time: <br />20:03 <br />20:03 <br />20:57 <br />20:57 <br />Finish psi: <br />15 <br />15 <br />15 <br />15 <br />Vol change cc: <br />6 <br />8 <br />4 <br />6 <br />Test 2: Start time: <br />20:13 <br />20:13 <br />21:07 <br />21:07 <br />Finish psi: <br />15 <br />15 <br />15 <br />15 <br />Vol change cc: <br />3 <br />5 <br />2 <br />4 <br />Test 3: Start time: <br />20:13 <br />20:23 <br />21:17 <br />21:17 <br />Finish psi: <br />15 <br />15 <br />15 <br />15 <br />Vol change cc: <br />1 <br />2 <br />1 <br />2 <br />Final gph: <br />0.005 <br />0.008 <br />0.004 <br />0.006 <br />Result: <br />PASS <br />PASS <br />PASS <br />PASS <br />Pump type: <br />SUCTION <br />SUCTION <br />SUCTION <br />SUCTION <br />COMMENTS Pump make: <br />GILBARCO <br />GILBARCO <br />GILBARCO <br />GILBARCO <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 Printed 04/15/98 11.38 MSHAW <br />