Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MARTIN-BROWER CO 14704 FITE CT. STOCKTON July 06 2015 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping o V ❑R ❑COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V o R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CFR 112.5(a) Failed to amend Plan as necessary. <br /> According to the SPCC Plan, filters are located inside the storm drains around the diesel tanks; no filters were <br /> observed in the tanks. The Spill Prevention, Control, and Countermeasure (SPCC) Plan must be amended when there <br /> is a change in the facility design, construction, operation, or maintenance that materially affects its potential for a <br /> discharge, within 6 months of the change, and implemented as soon as possible, not later than 6 months following <br /> preparation of the amendment. Immediately make all necessary amendments to the SPCC Plan to accurately <br /> represent the procedures and policies currently in place at the facility. <br /> This is a repeat violation, Class II. <br /> 613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years. <br /> Copies of inspection and testing records for the SPCC Plan were not found on site. Inspections and tests must be <br /> conducted in accordance with the written procedures developed in the Spill Prevention, Control, and Countermeasure <br /> (SPCC) Plan. Records of these inspections and tests must be signed by the appropriate supervisor or inspector and <br /> kept on site with the SPCC Plan for a period of three years. Immediately locate a copy of all inspection and testing <br /> records for the last three years, maintain them on site, and submit copies to the EHD. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209)468-3440 07/06/2015 <br /> Page 3 of 4 <br />