My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
166
>
2800 - Aboveground Petroleum Storage Program
>
PR0515523
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2019 11:09:52 AM
Creation date
10/11/2018 3:54:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0515523
PE
2832
FACILITY_ID
FA0006289
FACILITY_NAME
VALLEY PACIFIC PETROLEUM SERVICES
STREET_NUMBER
166
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342003
CURRENT_STATUS
01
SITE_LOCATION
166 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
259
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
In-Service AST Inspection Report <br /> Formal External Inspection of 8,500 Gallon Tank(AST-6) <br /> Valley Pacific Petroleum Services,Inc. <br /> Page 3 <br /> 1.4. The age of the tank, February 1992, was established using a UL/manufacturer nameplate <br /> observed on the tank. <br /> 1.5. The fabrication of AST-6 was inspected using STI SP001 and UL 142 guidelines and <br /> national standards as a baseline. <br /> 1.6. The tank foundation was inspected for indications of settlement, cracking, exposed rebar, <br /> and general disrepair. Cracks were observed in the concrete floor; however, due to water <br /> in the containment area,further investigation of the cracks was not possible. <br /> 1.7. The tank's steel supports were inspected for indications of cracking, spalling, and general <br /> disrepair. The supports are equipped with steel saddles welded and sealed to the tank <br /> surface limiting corrosion potential between the saddles and tank surface.The supports and <br /> saddles appear to be in fair condition and secured to the foundation with bolts. <br /> 1.8. The single-wall tank is located within a masonry block/concrete secondary containment <br /> structure with sufficient capacity for the entire tank contents.The tank is elevated providing <br /> a suitable Continuous Release Detection Method(CRDM). <br /> 1.8.1. The secondary containment structure was inspected for indications of settlement, <br /> cracking, exposed rebar, and general disrepair. Minor cracks were noted in the <br /> concrete floor; however, water in the containment area prevented further <br /> investigation of the cracks severity. <br /> 1.8.2. The secondary containment structure was inspected for foreign materials and for <br /> liquid in the containment area. Pooled liquid was present and likely a result of <br /> recent rain activity.Depth of the water in containment ranged from 6"to 12"deep. <br /> A spotty sheen was observed on the water surface. <br /> 1.8.3. The secondary containment walls and drain valves were inspected for penetrations. <br /> Drain valves were not observed and the containment walls showed no signs of <br /> penetrations through the secondary containment that may compromise the integrity <br /> of the containment area. A square sump without a pump was identified along the <br /> southwest end of the containment structure. Further inspection of the sump was <br /> obstructed by the water in containment. <br /> 1.9. Ancillary equipment was inspected for condition and operability. <br /> 1.9.1. Piping and piping connections were inspected for visible signs of stress or leakage <br /> such as severe corrosion, rusted bolted connections, or other severe degradation. <br /> Piping and piping connections were observed to be in good condition. <br /> ASTs have specific fittings that are generally accepted per industry standards or <br /> are required by applicable regulations. The following observations were made of <br /> fittings installed on AST-6: <br /> • Three topside 4-inch National Pipe Thread (NPT) couplers reduced to 2-inch <br /> pump connections. <br /> • Three topside 4-inch NPT couplers to 4-inch "T" fittings reduced for 3-inch <br /> fill pipe connections and reduced for 2-inch observation ports/loose fill <br /> fittings. <br /> • Three topside 4-inch NPT couplers reduced to 3/4-inch fittings for liquid level <br /> gauges. <br /> • Three topside 4-inch NPT coupler reduced 2-inch normal vent riser pipes with <br /> screen vent caps. <br /> • Three topside 24-inch long-bolt manways — approved for emergency release <br /> ventilation(ERV) <br /> • Two top side center of tank lift points. <br /> • Two bottom side 1-inch NPT couplers with gate valves located below each <br /> tank head. <br /> 1� <br /> i� CONDOR <br />