My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
2941
>
2800 - Aboveground Petroleum Storage Program
>
PR0527865
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2020 1:57:09 PM
Creation date
10/16/2018 10:34:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0527865
PE
2835
FACILITY_ID
FA0009657
STREET_NUMBER
2941
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206-1149
APN
48906-1
CURRENT_STATUS
01
SITE_LOCATION
2941 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
updated to reflect current quantity stored in gallons for each container at each facility. (5) <br /> Name change from "Exxon Additive" tank to "CFI 1935KK1 Diesel Additive". (6) <br /> Added railcar container volumes. (7) Added cathodic protection Oil Filled Containers and <br /> volumes. (8) Added Conductivity Skids that house 55 gallon drums of HiTec 4507 Diesel <br /> Additive. (9) Calculations for diesel Railcar transloading area were added (rail loading/ <br /> unloading area). <br /> (24) SPCC Plan failed to include required contact list and phone numbers of the facility's <br /> response coordinator, cleanup contractors, and agencies to notify in case of discharge <br /> • SPCC Plan has been updated to show the Emergency Coordinator's title by the name of <br /> the Qualified Individual (s) responsible. <br /> (27) SPCC Plan failed to include a description of potential equipment failure (direction, flow <br /> rate, quantity), or provide equivalence as allowed by CRG 112.7(a)(2) <br /> • The SPCC Facility Tank Inventory list has been updated to include all 55 gallon drums, <br /> and 350 gallon totes of red dye in the hazardous waste storage area, and railcars on site. <br /> • The SPCC Tank Inventory list has been updated to include the correct type oil and <br /> storage capacity of each fixed storage container by type. <br /> • The SPCC Tank Inventory list includes a prediction of the direction flow rate and total <br /> quantity of oil which could be discharged. <br /> (33) Failed to describe how the oil handling, processing and storage areas are secured and <br /> controlled; how master flow and drain valves are secured; how unauthorized access to starter <br /> controls on oil pumps are prevented; how out-of-service and loading/unloading connections are <br /> secured; the appropriateness of security lighting; or provide equivalence as allowed by CFR <br /> I I2.7(a)(2) <br /> • Figure C-4 Security Facility Lighting Section — SPCC Plan has been updated to say - <br /> Lighting is adequate throughout the tank farm to illuminate the piping connections at <br /> each storage tank and pump manifold area to both prevent acts of vandalism and assist in <br /> the discovery of product discharge. <br /> • All connections both in service and out of service are secured within the terminal fence <br /> line and are controlled by secure automated log-in secure to each individual. <br /> HAZARDOUS WASTE GENERATOR INSPECTION: <br /> (30) An empty HW or Haz Mat container (larger than 5 gallons) was not marked with the date it <br /> was emptied and/or not managed with one year of being emptied. <br /> 0 Completed on site <br />
The URL can be used to link to this page
Your browser does not support the video tag.