Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> COUN'T'Y <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A.A. & BOB ALLEN INC 2904 BEYER LN, STOCKTON November 13, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112. <br /> This facility has an Aboveground Petroleum Storage Act(APSA)regulated shell capacity greater than 10,000 <br /> gallons. A Spill Prevention, Control, and Countermeasure(SPCC) Plan was not available on site. All facilities which <br /> have an APSA regulated shell capacity of 1,320 gallons or greater shall prepare a written SPCC Plan which meets <br /> all of the requirements of the 40 CFR Part 112. This plan shall be certified by a professional engineer in accordance <br /> with 40 CFR 112.3(d). Immediately prepare a SPCC Plan in accordance with 40 CFR Part 112,which that includes <br /> all aboveground petroleum storage containers 55 gallons or larger. Submit a copy of the Professional Engineer <br /> (PE)certified SPCC Plan to the EHD for review. (This copy will be returned to the facility after review.) A copy <br /> shall be maintained on site at all times. <br /> This is a repeat violation, Class II. <br /> 103 HSC 25270.6(a) Failed to file HMBP or annual facility tank statement. <br /> The facility stated"no,"on the business activities page on CERS, and did not make an APSA submittal. A tank <br /> facility statement or business plan has not been submitted.A tank facility statement identifying the name and <br /> address of the tank facility, a contact person for the tank facility,the total storage capacity of the tank facility, and the <br /> location, size, age, and contents of each storage tank that exceeds 10,000 gallons in capacity and that holds a <br /> substance containing at least 5 percent of petroleum shall be submitted annually. Submittal of a business plan <br /> satisfies the requirement to submit a tank facility statement. Immediately submit a tank facility statement or <br /> business plan. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 106 CCR 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on November 15, 2013 and an inspection report was issued identifying information to <br /> be submitted to bring this site into compliance. The past violation includes"Failure to prepare a written SPCC Plan <br /> in accordance with CFR Part 112."This information was required to be submitted within 30 days. This information <br /> has not been received resulting in a non-compliant status for this facility. An operator that receives an inspection <br /> report shall have 30 days to submit a written response that includes a statement documenting corrective actions <br /> taken or proposing corrective actions which will be taken. Ensure that a written response documenting corrective <br /> actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receipt of this report. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all new(or any changes to <br /> existing)Aboveground Petroleum Storage Act (APSA) information online to the California Environmental <br /> Reporting System (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required <br /> FA0009388 PR0523480 SCO01 11/13/2017 <br /> EHD 28-01 Rev.09/22/16 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />