Laserfiche WebLink
OPW 10 Series Emergency Shut -Off Valves <br />Female Threaded Top (Outlet) Connection Valves <br />Ordering Specifications <br />Body Size Connection Poppet <br />Model No. in. cm Threads Configuration <br />kEC' <br />; _ 7 2017 <br />ENVIRONMENTAL HEALTH <br />DEPARTMENT <br />Replacement <br />Application Top <br />10BF-5725 1'h 4 <br />NPT <br />Single <br />Pressure <br />10RFT-5750 <br />10BFP-5726 1'h 4 <br />NPT <br />Double <br />Pressure <br />1OFTP-5701 <br />1ORF-2001 2 5 <br />NPT <br />Single <br />Pressure <br />1ORFT-5742 <br />1ORFP-2002 2 5 <br />NPT <br />Double <br />Pressure <br />1ORFTP-5752 <br />Male Threaded -Top (Outlet) Connection Valves <br />Body Size Connection <br />Model No. in. kg Threads <br />Poppet <br />Configuration <br />Application <br />Replacement <br />Top <br />10BM-5825 11h 4 <br />NPT <br />Single <br />Pressure <br />10RMT-5850 <br />1OBHMP-5830 11h 4 <br />NPT <br />Double <br />Pressure <br />10RMTP-5851 <br />10SSHMP-5830 11h 4 <br />NPT <br />Double <br />Suction <br />10SHMTP-5811 <br />1ORM-2003 2 5 <br />NPT <br />Single <br />Pressure <br />1ORMT-5842 <br />1ORMP-2004 2 5 <br />NPT <br />Double <br />Pressure <br />1ORMTP-5852 <br />Union -Top (Outlet) Connection Valves <br />Model No. in. kg <br />Connection <br />Threads <br />Poppet <br />Configuration <br />Application <br />Replacement <br />Top <br />10BU-5925 11h 4 <br />NPT <br />Single <br />Pressure <br />10RUTC-5975 <br />10BUP-5926 11h 4 <br />NPT <br />Double <br />Pressure <br />10UTCP-5901 <br />10SBUP-5926 11h 4 <br />NPT <br />Double <br />Suction <br />10SUTCP-5911 <br />10RU-2005 2 5 <br />NPT <br />Single <br />Pressure <br />10RUTC-5962 <br />10RUP-2006 2 5 <br />NPT <br />Double <br />Pressure <br />10RUTCP-5972 <br />Note: All BSPP Thread Shear Valves must be ordered through Europe or China office. <br />IMPORTANT NOTICE: <br />When mounting the OPW 10 Series Emergency Shut-off Valves, the anchoring system employed must withstand a force greater than 650 ft. pounds per valve. <br />NFPA Code 30A, Automotive and Marine Service Station Code, requires that the automatic closing feature of emergency shut-off valves be checked at least once per <br />year by manually tripping the hold -open linkage. OPW recommends the use of Flexworks Stabilizer Bar Support System for proper mounting of 10 Series Valves. <br />................................ ............._.......................................... ......................... .......................__.._............ ..... ..... ................ <br />NOTICE: <br />As per NFPA 30A, electrical supply to the submersible pump <br />must always be disconnected before servicing meters, <br />dispensers or emergency shut-off valves. <br />OPVV. <br />W <br />A EnOY@zi cAYa4~ <br />