My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:27:51 PM
Creation date
10/19/2018 10:08:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
663
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L.D <br /> 2017 <br /> Vaporless 99 LD-2000 Addendum <br /> " Lrl'—EALTH <br /> 1.0 Introduction <br /> This report contains the results of testing conducted on the 99 LD-2000. A limited <br /> number of tests were conducted which were designed to verify that the 99 LD-2000 could <br /> detect a 3 gal/h leak in the same manner as the original LD 2000 mechanical line leak <br /> detector. Testing was performed in accordance with the EPA Pipeline Leak Detection <br /> Test Protocoll with the exception of the number of tests performed 2 <br /> This report is to be used in conjunction with the November 19, 1990 evaluation of the <br /> Vaporless LD 2000 mechanical line leak detector.3 Several evaluations have been <br /> conducted on various LD 2000 models to determine performance parameters.4 The <br /> original LD 2000 evaluation (November 19, 1990) was conducted on a rigid pipeline that <br /> was 176 ft. in length by 3 3/8 inches in diameter with a volume of 81.5 gallons. The <br /> results of the testing determined that the LD 2000 had an estimated probability of <br /> detection (PD)of 100% with an upper confidence interval of 92 to 100% and an estimated <br /> probability of false alarm (PFA) of 0% with a lower confidence limit of 0 to 8%. <br /> 1 "Standard Test Procedures for Evaluating Leak Detection Methods: Pressurized <br /> Pipeline Leak Detection Systems", EPA/530/UST-90/010, September, 1990. <br /> 2 The EPA protocol requires that 50 tests be conducted under various conditions <br /> for a full evaluation. This evaluation consisted of 6 tests on a rigid line and 6 tests on a <br /> flexible line. <br /> 3 Performance Evaluation of the Vaporless LD 2000 Line Leak Detector, Final <br /> Report, For Vaporless Manufacturing,November 19, 1990, Ken Wilcox Associates, Inc. <br /> 4 Three previous evaluations were conducted on versions of the LD-2000 for <br /> Hourly Testing. Evaluation reports written by KWA, Inc. for the following models of the <br /> LD-2000 are available from Vaporless Manufacturing: LD-2000 and LD-2000S, <br /> 11/19/90; LD-2000E and LD-2000E-S, 12/11/92; LD-2000T and LD-2000T-S, 7/13/93. <br /> Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.