Laserfiche WebLink
Vaporless 99 LD2000 Addendum <br />Table 1. Data and Results for Testing Conducted on Rigid Pipeline <br />Test <br />No. <br />Date Test <br />Began <br />Time Time <br />Circulation Circulation <br />Started Ended <br />Time Data <br />Collection <br />Began <br />Time Data <br />CollectionCirculation <br />Ended <br />Duration of <br />Circulation <br />Time Between End of <br />and Start of <br />Data Collection <br />Duration of <br />Data <br />Collection <br />T(TB) <br />(Product <br />Temp.) <br />T(G) <br />(Ground <br />Temp.) <br />T(TB)-T(G) <br />(Temp. <br />Differential) <br />Temp. Matrix <br />Category <br />Induced Leak <br />Rate <br />Measured <br />Test Result <br />o <br />mm/dd/yy <br />hhmm hhmm <br />hhmm <br />hhmm <br />hhmm <br />hhmm <br />hhmm <br />deg F <br />deg F <br />deg F <br />deg F <br />gal/h <br />�t <br />Test <br />Date Test <br />Time <br />Time <br />Time Data <br />Time Data <br />Duration of <br />Time Between End of <br />Duration of <br />T(TB) <br />T(G) <br />T(TB)- T(G) <br />1 <br />10/14/1998 <br />1045 1145 <br />1145 <br />1145 <br />0100 <br />0000 <br />0000 <br />66.74 <br />65.60 <br />1.14 <br />+5 to -5 <br />0 <br />Tight <br />2 <br />10/14/1998 <br />1045 1145 <br />1145 <br />1146 <br />0100 <br />0000 <br />0001 <br />66.74 <br />65.60 <br />1.14 <br />+5 to -5 <br />3.0 <br />Leak <br />3 <br />10/15/1998 <br />0925 1025 <br />1025 <br />1025 <br />0100 <br />0000 <br />0000 <br />37.40 <br />63.43 <br />-26.03 <br /><-25 <br />0 <br />Tight <br />4 <br />10/15/1998 <br />0925 1025 <br />1025 <br />1026 <br />0100 <br />0000 <br />0001 <br />37.40 <br />63.43 <br />-26.03 <br /><-25 <br />3.0 <br />Leak <br />5 <br />10/15/1998 <br />1340 1440 <br />1440 <br />1500 <br />0100 <br />0000 <br />0020 <br />88.34 <br />63.54 <br />24.80 <br />> +25 <br />it 0 <br />Tight <br />6 <br />10/15/1998 <br />1340 1440 <br />1500 <br />1505 <br />0100 <br />0020 <br />0005 <br />88.34 <br />63.54 <br />24.80 <br />> +25 <br />_3.0 <br />Leak <br />C <br />Table 1. Data and Results for Testing Conducted on Flexible Pipeline <br />r� <br />Page 4 <br />o <br />�t <br />Test <br />Date Test <br />Time <br />Time <br />Time Data <br />Time Data <br />Duration of <br />Time Between End of <br />Duration of <br />T(TB) <br />T(G) <br />T(TB)- T(G) <br />Temp. Matrix <br />induced Leak <br />Measured <br />No. <br />Began <br />Circulation <br />Circulation <br />Collection <br />Collection <br />Circulation <br />Circulation and Start of <br />Data <br />(Product <br />(Ground <br />(Temp. <br />Category <br />Rate <br />Test Result <br />Started <br />Ended <br />Began <br />Ended <br />Data Collection <br />Collection <br />Temp.) <br />Temp.) <br />Differential) <br />mm/ddhy <br />hhmm <br />hhmm <br />hhmm <br />hhmm <br />hhmm <br />hhmm <br />hhmm <br />deg F <br />deg F <br />deg F <br />deg F <br />gal/h <br />In <br />67.28 <br />63.84 <br />7 <br />10/14/98 <br />1155 <br />1255 <br />1255 <br />1255 <br />0100 <br />0000 <br />0000 <br />3.44 <br />+5 to -5 <br />0 <br />Tight <br />8 <br />10/14/98 <br />1155 <br />1255 <br />1255 <br />1256 <br />0100 <br />0000 <br />0001 <br />67.28 <br />63.84 <br />3.44 <br />+5to-5 <br />3.0 <br />Leak <br />9 <br />10/14/98 <br />1405 <br />1505 <br />1505 <br />1505 <br />0100 <br />0000 <br />0000 <br />38.30 <br />64.42 <br />-26.12 <br /><-25 <br />0 <br />Tight <br />10 <br />10/14/98 <br />1405 <br />1505 <br />1505 <br />1506 <br />0100 <br />0000 <br />0001 <br />38.30 <br />64.42 <br />-26.12 <br /><-25 <br />3.0 <br />Leak <br />11 <br />10/15/98 <br />1230 <br />1330 <br />1330 <br />1330 <br />0100 <br />0000 <br />0000 <br />87.80 <br />61.86 <br />25.94 <br />> +25 <br />0 <br />Tight <br />12 <br />10/15/98 <br />1230 <br />1330 <br />1330 <br />1331 <br />0100 <br />0000 <br />0001 <br />87.80 <br />61.86 <br />25.94 <br />> +25 <br />3.0 <br />Leak <br />Page 4 <br />