My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 11:15:30 AM
Creation date
10/19/2018 3:11:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2014 - 2015
FileName_PostFix
2014 - 2015
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siciov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Facility Inspection <br />Name: Loves County Store #223 Address: 1553 Colony Drive, Ripon Date: Aug 12, 2014 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I. CLASS II. or MINOR -Notice to Comply) <br />Onsite to conduct a routine underground storage tank inspection and observe monitoring system <br />certification conducted today. A line test was conducted in lieu of positive shut down. <br />Class 11 Violations: 204, 311, 313 <br />204. The designated operator failed to document all the alarms from the attached alarm history on the <br />March 2014 and June 2014 designated operator monthly inspection reports and failed to check that they <br />were responded to appropriately. The missing alarms include: L10 alarm on February 28, 2014 and May <br />15, May 28 and June 16, 2014 alarms associated with testing conducted during the most recent UDC <br />upgrade. During the monthly inspection, the designated operator shall review the alarm history for the <br />previous month, check that each alarm was documented and responded to appropriately, and attach a <br />copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. While onsite, the designated operator documented all <br />aforementioned alarms. CORRECTED. <br />311. Both diesel grade (tank 4 and tank 5) line leak detectors failed to detect a leak when tested. All <br />line leak detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a <br />properly licensed, trained, and certified contractor repair or replace the failed leak detector (LG 113-x <br />listed, if applicable) and obtain a permit within one business day from the EHD. If the failed leak <br />detectorjcan't be replaced immediately, there is a possibility that diesel UST system may be red <br />tagged to prevent fuel inputs. <br />313. The diesel spill container (located closest to the convenience store, western diesel tank) failed <br />when tested. All spill containers shall have a minimum capacity of five gallons and be capable of <br />containing a spill or overfill until it is detected or cleaned up. Immediately contact a properly licensed, <br />trained, and certified contractor to repair or replace the spill container under permit and inspection of the <br />EHD. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION Y TIME AT EHD'S CURRENT HO RLY RATE. <br />Inspector Re ed By. <br />EHD 23-02 Rev 04/19/12 Paq,13 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.