My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 11:15:30 AM
Creation date
10/19/2018 3:11:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2014 - 2015
FileName_PostFix
2014 - 2015
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton,Calitomia 95205-6232 <br /> Telephone. (209)488-3424 Fax:(209)468-8433 Web:wwvv. inov.oralehd <br /> UNDERGROUND STORAGE TANK(UST)PROGRAM INSPECTION REPORT CONTINUED <br /> Fscil fy <br /> Name: Loves County Stare#223 Fac"'y Address: 1553 Colony Drive Ripon nate tnspectlon Aug 12, 2414 <br /> VIOLATIONS <br /> C1 G2 Y Code$aetlon HSC-=CA Health and Code:CFR=Code of Fed�l R ule7one <br /> Cl=Clem 1 vlde8oc4 C2-ca!2 M M FAMW mon {p <br /> C�+r.?i',I'f <br /> :.,u. .i.- .., .. rt -� ./.t-;,,. ., <., .t;" Y•. .'� <br /> 702 CCR 2643(x) Biennial i ess test of iia- p piping not ad Orc-January 1.1984) flM1) <br /> 703 CCR 2643(d) Tnonlnial fine test for owverrponal suctlon piping not perjimmed(pra-January 1,1984) M l s t�1 <br /> 999 meter See afladned'Cr�m,abon—Official In cion torvlotatlare(s)not fisted spare_ <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MIMOR-Notice to Com <br /> Onsite to conduct a routine underground storage tank inspection and observe monitoring system <br /> certification conducted today_ A line test was conducted in lieu of positive shut down. <br /> Class 11 Violations: 204, 311, 313 <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> March 2014 and June 2014 designated operator monthly inspection reports and failed to check that they <br /> were responded to appropriately. The missing alarms include: L10 alarm on February 28, 2014 and May <br /> 15, May 28 and June 16, 2014 alarms associated with testing conducted during the most recent UDC <br /> upgrade_ During the monthly inspection, the designated operator shall review the alarm history for the <br /> previous month, check that each alarm was documented and responded to appropriately, and attach a <br /> copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. While onsite, the designated operator documented all <br /> aforementioned alarms. CORRECTED. <br /> 311. Both diesel grade (tank 4 and tank 5) line leak detectors failed to detect a leak when tested. All <br /> line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. Immediately have a <br /> properly licensed, trained, and certified contractor repair or replace the failed leak detector (LG 113-x <br /> listed, if applicable) and obtain a permit within one business day from the EHD. if the failed leak <br /> detector can't be replaced immediately,there is a possibility that diesel UST system may be red <br /> tagged to prevent fuel inputs_ <br /> 313. The diesel spill container(located closest to the convenience store, western diesel tank) failed <br /> when tested- All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. Immediately contact a properly licensed, <br /> trained, and certified contractor to repair or replace the spill container under permit and inspection of the <br /> EHD. <br /> ALL FHO STAFF TANS ASSMATED VpTH FA"Na TO COMPLY BY THE ABOVE NUT®OATES VALL 6E 61LLED AT THE CURRENT HOURLY RAT£ <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inq)@Mr. aeceiund By: <br /> T INSPECTION REPORT <br /> F-HD 23-02 Rev 04119/12 page 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.