My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MUNFORD
>
3730
>
2800 - Aboveground Petroleum Storage Program
>
PR0531150
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2019 4:35:42 PM
Creation date
10/22/2018 9:22:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0531150
PE
2832
FACILITY_ID
FA0014437
FACILITY_NAME
NORCAL TRANSPORT REFRIGERATION
STREET_NUMBER
3730
Direction
E
STREET_NAME
MUNFORD
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
17956010
CURRENT_STATUS
01
SITE_LOCATION
3730 E MUNFORD AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> CONTINUATION FORM Page: 2 of 2 <br /> OFFICIAL INSPECTION REPORT Date: 05/29/13 <br /> Facility Address: 3730 Munford Ave., Stockton Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> --The facility diagram did not include the 55 gallon drums on site. The Plan shall include a facility <br /> diagram which must mark the location and contents of each fixed storage container and the storage area <br /> where mobile or portable containers are located. It must identify the location of and mark as "exempt" <br /> underground tanks. It must also include all transfer stations and connecting pipes, including intra-facility <br /> gathering lines. The map was updated by Mr. Carsey at the time of review. <br /> --The SPCC Plan does not include the used oil tank on the east outer wall of the shop. Discharge & <br /> drainage controls and potential equipment failure are not addressed for this tank. The SPCC Plan must <br /> include the correct type of oil and storage capacity of each fixed storage container, and either the type of <br /> oil and storage capacity of each portable container or an estimate of the potential number of portable <br /> containers, types of oil, and anticipated storage capacities. The Plan must include discharge or <br /> drainage controls, such as secondary containment around all containers and other structures, <br /> equipment, and procedures for the control of a discharge, and a prediction of the direction, rate of flow, <br /> and total quantity of oil which could be discharged as a result of each type of major equipment failure. <br /> Immediately update the inventory and discharge information in the SPCC Plan to accurately represent <br /> the petroleum storage at the facility, or update the tank storage at the facility to match the inventory <br /> listed in the Plan. <br /> According to Mr. Carsey, the used oil tank will be discontinued and the site will begin using a 55 gallon <br /> drum for used oil storage in the future. In order to be excluded from SPCC Plan requirements, <br /> petroleum storage containers must either be removed from the site or meet all of the following <br /> requirements: <br /> (1) All liquid and sludge has been removed from each container and connecting line <br /> (2) All connecting lines and piping have been disconnected from the container and blanked off <br /> (3) All valves (except for ventilation valves) have been closed and locked <br /> (4) Conspicuous signs have been posted on each container stating that it is a permanently closed <br /> container and noting the date of closure <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> Stacy Rivera (209) 468-3440 <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.