Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sjgov.or./q ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: FFebrua <br /> ate: <br /> NORCAL TRANSPORT REFRIGERATION 3730 E MUNFORD AVE STOCKTON 02 2016 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping, and appurtenances ❑V ❑R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ■V ❑R ❑COS <br /> 728 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 HSC 25270.4.5(a) Failed to properly close a tank that is considered permanently closed. <br /> The two permanently closed tanks on site were observed with "permanently closed" labels, but no date of closure. <br /> When a tank is not in use, it must be permanently closed by meeting the following conditions: <br /> - remove all liquid and sludge from each container and connecting line <br /> -disconnect and blank off all connecting lines and piping have from the tank <br /> -close and lock all valves <br /> - post a sign conspicuously stating that it is a permanently closed container and denoting the date of closure. <br /> Immediately"Permanently Close" all tanks that are not being used or amend the Spill Prevention, Control, and <br /> Countermeasure Plan to include all petroleum tanks that have not been permanently closed. <br /> This is a minor violation. <br /> 605 CFR 112.7(a)(3) Plan failed to address facility layout, operations discharge prevention methods and containers. <br /> The used oil tank is not included in the Plan inventory. The following shall be addressed in the Spill Prevention, <br /> Control, and Countermeasure (SPCC) Plan: <br /> -type of oil in each fixed container and it's storage capacity. For mobile or potable containers, the type of oil and <br /> storage capacity for each container or an estimate of the potential number of mobile or portable containers, the types <br /> of oil, and anticipated storage capacities <br /> -discharge prevention measures including procedures for routine handling of products <br /> -discharge or drainage controls such as secondary containment, equipment, and procedures for the control of a <br /> discharge <br /> -countermeasures for discharge discovery, response, and cleanup <br /> - methods of disposal of recovered materials <br /> -contact list and phone numbers for the facility response coordinator, National Response Center, cleanup <br /> contractors, and all appropriate Federal, State, and local agencies. <br /> Immediately amend the SPCC Plan to include all required information. <br /> This is a Class II violation. <br /> Page 3 of 6 <br />