My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2800 - Aboveground Petroleum Storage Program
>
PR0539499
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2019 8:09:38 AM
Creation date
10/22/2018 9:29:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0539499
PE
2832
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Regional Transportation Center 2849 E Myrtle St, Stockton December 14, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 710 CFR 112.8(c)(6)Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> An industry standard for the inspection/testing of the tanks is not discussed in the SPCC plan. Each aboveground <br /> container shall be tested and inspected for integrity on a regular schedule and whenever repairs are made. The <br /> qualifications of personnel performing tests and inspections,frequency and type of testing and inspections that take <br /> into account container size, configuration, and design shall be determined in accordance with industry standards. <br /> Examples of these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic <br /> testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing. Comparison <br /> records and other records of inspections and tests must be maintained on site. Include a discussion of the industry <br /> standard(s)considered appropriate for the tanks at described in the SPCC Plan , or provide equivalence as allowed <br /> by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 4010 The SPCC Plan did not contain "ATTACHMENT C-11—CERTIFICATION OF THE APPLICABILITY <br /> OF THE SUBSTANTIAL HARM CRITERIA"of CFR part 112. If the facility does not meet the substantial harm <br /> criteria listed in Attachment C-1 of CFR part 112, the owner or operator shall complete and maintain at the facility <br /> the certification form contained in Attachment C-11 to this appendix. In the event an alternative formula that is <br /> comparable to the one in this appendix is used to evaluate the substantial harm criteria,the owner or operator shall <br /> attach documentation to the certification form that demonstrates the reliability and analytical soundness of the <br /> comparable formula and shall notify the Regional Administrator in writing that an alternative formula was used. <br /> Complete"ATTACHMENT C-11—CERTIFICATION OF THE APPLICABILITY OF THE SUBSTANTIAL HARM <br /> CRITERIA"and provide a copy to the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by January 13, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: December 14, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> John Coose, Facilities Supervisor <br /> FA0022301 PR0539499 SCO01 12/14/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.