Laserfiche WebLink
� • i <br /> GENERAL INFORMATION: <br /> 3_. Y <br /> 1. Obtain EPA Site Number from the Department of Health Services (916) 324-1 31'fav tempot 2 <br /> hazardous waste retnavai acuvides assomated with underground tank remo�Y �- <br /> 2. Disposal Infor=uon: Public Health Setvicas Traclan sheet will accompany <br /> site. Tank(s) will be issued as identification number which PHS-=' n�ee�noteed on <br /> the Tank Tracking Sheet and Contractor will affix same ID Number onto tank end using fluorescent <br /> sPmY PaML Contaminated tank/piping are to be transported under Hazardous Waste Manifest by a <br /> registered hazardous waste hauler, <br /> 3. Contractor to Provide; CombusublelFlammable gas detector to verify the Lower F-cplosive Limit <br />' (LEL) atmosphere and oxygen level of tank prior to lifting from excavation, adequate number and <br /> appropriate type(s) of fire eutinguisher(s), banners to secure the area as necessary to mu maze traffic <br /> and pedestrian interfcrence,and fluorescent sprav paint to affix mnk(s)identification number. It shall <br /> be the project manager's responsibihry for compliance with all health & safery precautions and <br /> requirements,which shall be strictly adhered to at all tunes during the course of the closure acuvities. <br /> 4 The PHS-EHD permit shall be on site during excavation and removal. <br /> iS Any changes in this document must be approved by this department pnor to initiating work. <br /> 6. Closure-In-Place: If Closuro-in-Place is the suggested method of abandonment, complete form <br /> EH 23 039 and submit written approval from the zonal Fire Department, <br /> 7 Temporary Closure: If Temporary Closure is the suggested method of abandonment, complete <br /> form EH 23 046 and submit written approval from the local Fire Department. <br /> S. The following shall be submitted 30 days after tank removal date: <br /> i <br /> a) Analyucal results, mailed directly from laboratory to PHS, with a chain of custody. <br /> b) Tank Tracking Record Sheet(s) and/or Hazardous Waste Manifest(s). <br /> C) Hazardous Waste Manifests for ansate, residual fuel, waste oil receipt, and piping. <br /> d) Submit a compaction report as required b San Joaquin Cour <br /> Y quin ry and its incorporated City <br /> Building Departments. This report will be referred to the appropnate agency for their <br /> renew. <br /> A site which has had UST(s)removed,shall not be considered for Unal closure until the above Items <br /> are submitted for review. <br /> Page 2 <br />' EH23 040 <br />