Laserfiche WebLink
APPENDIX C <br /> PURGE VOLUME CALCULATIONS <br /> Ralph's Square <br /> 404 Aldo Avenue, Santa Clara, California <br /> Time Formula: <br /> E= total volume to be purged <br /> F= purge rate (200ml/min peristaltic pump) <br /> G= 60 seconds/min <br /> H= total purge time in seconds at 200 ml (cc) per min <br /> H= (E/F)G <br /> H= 687.46 x 1 min x 60 sec <br /> 200ml 1 min <br /> Total purge time= 206.24 sec <br /> or <br /> 3.44 min <br />