Table 7 <br /> Remediatlon System Air Emisslons <br /> ATC#N-298-15-0 <br /> The Earthgrains Company <br /> 2651 South Airport Way <br /> Stockton,California 95206 <br /> 1 Date AT C(inf) Q(inf) C(eff) Q(eff) PE(unc) PE(con) Total PE(unc) Total PE(con) <br /> 04/25/2001 0 1040 30 12 88 0 0 0 0 <br /> 05/02/2001 7 1040 30 12 88 7120 024 7120 024 <br /> 05/09/2001 5 299 20 144 70 975 016 8095 041 <br /> 05/16/2001 7 668 20 29 85 3049 056 11143 097 <br /> 05/23/2001 7 444 50 428 95 5066 093 16209 1 90 <br /> 1 06/04/2001 12 683 60 119 100 16031 4655 32241 4845 <br /> 06/06/2001 0 0 0 32241 4845 <br /> 06/13/2001 6 1090 25 037 95 5330 007 37571 4852 <br /> 06/20/2001 65 450 15 106 95 1430 213 39001 6065 <br /> ' 06/27/2001 68 489 30 726 95 3252 1 53 42253 5218 <br /> 07/04/2001 7 535 20 086 97 2442 019 44695 5237 <br /> 07/11/2001 7 157 22 013 98 788 003 45483 5240 <br /> 07/18/2001 7 243 25 396 99 1386 089 46869 5329 <br /> 07/25/2001 7 564 22 431 98 2832 964 49701 6293 <br /> 08/23/2001 0 0 0 49701 6293 <br /> 08/29/2001 6 491 32 046 100 3073 009 52774 6302 <br /> 09/05/2001 7 517 32 0 359 100 3775 008 56550 6310 <br /> 09/12/2001 7 541 30 346 99 3704 078 60253 6389 <br /> 09/19/2001 7 612 32 993 100 4469 2266 64722 8655 <br /> 09/26/2001 7 501 20 110 95 2287 2385 67009 11039 <br /> 09/28/2001 0 000 000 67009 11039 <br /> 10/03/2001 5 399 32 0 166 96 2081 003 69090 11042 <br /> 10/10/2001 7 302 30 0 756 90 2067 016 711 58 11057 <br /> 10/17/2001 7 323 25 910 100 1843 208 73000 11265 <br /> 10/31/2001 0 <br /> Where <br /> AT= Days of operation since last sampling event <br /> ' C(mf)= Influent concentration to ppmv TPH <br /> Q(mf)= Influent flow rate in cubic feet per minute <br /> C(eff)= Effluent concentration in ppmv TPH <br /> Q(ef)= Effluent flaw rate in cubic feet per minute <br /> PE(unc)= Potential to emit(uncontrolled)in pounds since previous sampling <br /> PE(eonc)= Potential to emit(controlled)in pounds since previous sampling <br /> Notes <br /> 1 1 During the 5/2/2001 the system was found to be inoperable due to damaged electrical controls which were repaired on May 4 2001 <br /> 2 Due to peak electncal power demands at the facility,the remediation unit has only been operated approximately 18 hrs per day since <br /> June 1,2001 The unit is manually turned off at noon each day and restarted at 6 00 p m <br /> 3 Due to elevated effluent ID readings the unit was shut down during the June 4 2001 visit <br /> 4 New secondary carbon vessel was Installed on June 6,2001 while the original secondary unit was moved to the primary position <br /> and the original primary unit was moved to the primary position and the original primary unit was removed from service <br /> 5 Primary and secondary carbon vessels were changed out on June 20,2001 using 160 Ib units for both positions <br /> 6 Primary carbon vessel replace with new 1,000 lb vessel June 22 2001 <br /> ' 7 Unit shut down on 7/25 pending carbon change out and carbon disposal acceptance <br /> 8 Unit put back Into operation on 8/23 with new carbon vessels(1,000 Ib primary and 160 Ib secondary) <br /> 9 Unit shut dawn on 9119 and moved secondary vessel to primary position while Installing new secondary vessel <br /> Then restarted unit <br /> 10 Unit shut down on 9126 pending carbon replacement(primary and secondary) <br /> 11 Unit re-started on 9/28 after carbon replacement <br /> 12 Unit shutdown on 10/17 pending carbon replacement <br /> 13 Unit restarted on 10131 after carbon replacement <br /> users162400132/121382/stockton/airemissions As <br />