My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
574
>
2300 - Underground Storage Tank Program
>
PR0231405
>
INSTALL 1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 2:06:00 PM
Creation date
10/26/2018 3:48:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL 1999
FileName_PostFix
1999
RECORD_ID
PR0231405
PE
2361
FACILITY_ID
FA0003164
FACILITY_NAME
A ONE GAS & FOOD
STREET_NUMBER
574
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
574 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AN ESOP COMPANY <br />r ROBERT H. LEE & ASSOCIATE%S, INC. <br />ARCFIITECTURE ENGINEERING • ENVIRONMENTAL SERVICES <br />1137 NORTH MCDOVVELL BOULEVARD • PETALUMA. CALIFORNIA 94954-1 1 10 (707) 785-1860 <br />Mailing Address: P.O. Box 750906. Petaluma. CA 94975-0908 Fr„ (707) 765-990e <br />Dear Sir: <br />1 have examined and reviewed the following items on the American Containmenr <br />"Amcon Elite Dispenser Sump" fol secondary containment: <br />1. A production run sump, complete with piping, fittings and emerl:!ncy <br />valves installed, at a petroleum equipment distributors facility. <br />2. National Technical Systems Fullerton Division Test Report 576-£:703 <br />on the structural integrity of the dispenser sump. <br />3. National Technical Systems Fullerton Division Test Report 576-£;703-1 <br />on leakage test of the dispenser sump. <br />4. Reichhold Letter regarding suitability of Reichhold 33-472 <br />Terephthalate and 6631T Isothalic resins. <br />5. Koppers Product Data for DION ISO 6631T Polyester Resin. <br />6. American Containment drawings for the Amcon Elite Dispenser Drip <br />Pan (4). <br />Upon review of the manufacturing procedures and the employment of the: <br />materials used in construction of the "AMCON ELITE DISPENSER SU:k�IP", <br />it is my opinion and conclusion that sound design and engineering of this <br />product will meet or exceed the secondary emergency containment of all <br />motor vehicle fuels and their additives currently used by the petroleum <br />marketing companies today. <br />en� Sincerely, <br />AZ <br />o- J lQ,l� y4r S <br />James H. Ray E>,, �2-'�•� <br />Civil Engineer - CIVIL <br />Of cALil <br />Li MARIETTA, GA 9ACRAMiNr0. CA eELLtvUE. WA Lt F trrr rr <br />June 7, 1995 <br />BRIAN F. ZITA <br />ArcPitcat <br />JOHN W. JOHNSON <br />American Containment <br />Ar`mit at <br />3510 Standard Street <br />o�h '"8 <br />Bakersfield, CA 93308 <br />tam° <br />cz <br />CECiL n. SOGNCER <br />AI`CnitACt <br />ATT: John Larsen <br />JAMES H. DAY <br />CJS I fnp noor <br />RE: ' THIRD PARTY APPROVAL Sec. 2631(d) <br />AMCON ELITE DISPENSER SUMP <br />CALIFORNIA WATER RESOURCE CONTROL BOARD <br />Dear Sir: <br />1 have examined and reviewed the following items on the American Containmenr <br />"Amcon Elite Dispenser Sump" fol secondary containment: <br />1. A production run sump, complete with piping, fittings and emerl:!ncy <br />valves installed, at a petroleum equipment distributors facility. <br />2. National Technical Systems Fullerton Division Test Report 576-£:703 <br />on the structural integrity of the dispenser sump. <br />3. National Technical Systems Fullerton Division Test Report 576-£;703-1 <br />on leakage test of the dispenser sump. <br />4. Reichhold Letter regarding suitability of Reichhold 33-472 <br />Terephthalate and 6631T Isothalic resins. <br />5. Koppers Product Data for DION ISO 6631T Polyester Resin. <br />6. American Containment drawings for the Amcon Elite Dispenser Drip <br />Pan (4). <br />Upon review of the manufacturing procedures and the employment of the: <br />materials used in construction of the "AMCON ELITE DISPENSER SU:k�IP", <br />it is my opinion and conclusion that sound design and engineering of this <br />product will meet or exceed the secondary emergency containment of all <br />motor vehicle fuels and their additives currently used by the petroleum <br />marketing companies today. <br />en� Sincerely, <br />AZ <br />o- J lQ,l� y4r S <br />James H. Ray E>,, �2-'�•� <br />Civil Engineer - CIVIL <br />Of cALil <br />Li MARIETTA, GA 9ACRAMiNr0. CA eELLtvUE. WA Lt F trrr rr <br />
The URL can be used to link to this page
Your browser does not support the video tag.