My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
525
>
2800 - Aboveground Petroleum Storage Program
>
PR0526379
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2019 4:38:06 PM
Creation date
10/29/2018 9:43:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0526379
PE
2832
FACILITY_ID
FA0002864
FACILITY_NAME
DAMERON HOSPITAL
STREET_NUMBER
525
Direction
W
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13715304
CURRENT_STATUS
01
SITE_LOCATION
525 W ACACIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> SAN JOAQUINYl i <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name : Facility Phone: Date : <br /> DAMERON HOSPITAL (209 ) 944-5550 October 25 , 2018 <br /> Facility Address : CERS ID : <br /> 525 W ACACIA ST , STOCKTON , CA 95203 10181003 <br /> Inspection Contact: Title. Phone: <br /> Jacob Wiebe Senior Director of plant (209 ) 944-5550 <br /> Inspection Type: Program : <br /> ROUTINE INSPECTION - Operating Permit 12832 - ASTFAC 10 K - </= 100 K GAL CUMULATIVE <br /> Consent For: Consent Given By : <br /> 0 Inspection I] Photos ❑ Samples I Jacob Wiebe , Senior Director of plant ops <br /> CCR = California Code of Regulations HSC = Health and Safety Code CFR = Title 40 Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> Aboveground Petroleum Storage Act <br /> 101 HSC 25270 . 6 (b) Failed to pay APSA program annual fees ❑ V ❑ R ❑ COS <br /> 102 HSC 25270 . 4 . 5 (a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 ❑ V ❑ R ❑ COS <br /> 103 HSC 25270 . 6(a) Failed to file HMBP or annual facility tank statement ■ V ❑ R ❑ COS <br /> 104 HSC 25270 . 8 Failed to report spills or releases of 42 gallons (one barrel) or more iiV ❑ R iiCOS <br /> 105 CFR 112A (b) (3) 1112 , 2 Failure to properly close tanks when making a claim of permanently closed ❑ V ❑ R ❑ COS <br /> 106 HSC 25404 . 1 . 2 Failed to submit a certification and written response within 30 days for minor violations ❑ V ❑ R ❑ COS <br /> 107 HSC 25270 . 2 (a) (4) Failure to prepare SPCC plan when facility no longer meets oil-filled electrical equipment exclusion ❑ V ❑ R ❑ COS <br /> 108 HSC 25270 . 4. 5(a) Failure of conditionally exempt facility to conduct inspections or install secondary containment ❑ V ❑ R ❑ COS <br /> 109 HSC 25270 . 2(o) ( 1 ) (C) Failure to have secondary containment and/or leak detection if TIUGA piping cannot be viewed ❑ V ❑ R ❑ COS <br /> (iv)( 111) <br /> 110 HSC 25404 (e) (4) Failed to report program data in the California Environmental Reporting System (CERS) ❑ V ❑ R ❑ COS <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112 . 3(d) Failure to have a licensed PE properly review and certify the SPCC plan ❑ V ❑ R ❑ COS <br /> 202 CFR 112 . 3 (e) ( 1 ) Failed to maintain a copy of the Plan on site ❑ V ❑ R ❑ COS <br /> 203 CFR 112 . 3 Failure to implement the SPCC Plan ❑ V ❑ R ❑ COS <br /> 204 CFR 112 . 3 (g ) Failure to prepare SPCC Plan when facility no longer meets Qualified Facility criteria ❑ V ❑ R ❑ COS <br /> 205 CFR 112 . 31 112 . 6 Failure to prepare SPCC Plan that meets all applicable requirements ❑ V ❑ R ❑ COS <br /> 206 CFR 112 . 3 (d)( 1 ) Failure of owner to assure that the PE makes all required attestations in the Plan ❑ V ❑ R ❑ COS <br /> Amendment of SPCC Plan by Owners or Operators <br /> 301 CFR 112 . 5 (a) Failed to amend Plan as necessary ❑ V ❑ R ❑ COS <br /> 302 CFR 112 . 5(b) Failed to review Plan once every five years and/or implement any resulting amendments ■ V ❑ R ❑ COS <br /> 303 CFR 112 . 5(c) Failed to have a PE certify technical amendments ❑ V ❑ R ❑ COS <br /> 304 CFR 112 . 5(a) , 112 . 5(b) Failure to implement SPCC plan amendments within 6 months ❑ V ❑ R ❑ COS <br /> Qualified Facility - Tier 1 <br /> 401 CFR 112 . 6 (a) , 112 . 6 (b) Tier I Qualified Facility Plan not certified by the owner or a PE ❑ V ❑ R ❑ COS <br /> 402 CFR 112 . 6 (a)(2) Owner of Tier I Qualified Facility failed to self certify technical amendment ❑ V ❑ R ❑ COS <br /> 403 CFR 112 . 6 (a) (3) (i) Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged ❑ V ❑ R ❑ COS <br /> 404 CFR 112 . 6(a) (3) (ii) No 2CT for bulk containers , or mobile storage containers not located to prevent discharge ❑ V ❑ R ❑ COS <br /> FA0002864 PR0526379 SC001 10/25/2018 <br /> EHD 28-01 Rev, 09/27/2018 Page 1 of 7 Aboveground Petroleum Storage Act OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 -3420 F 209 464 -0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.