Laserfiche WebLink
Hazardous Waste Tank System July <br /> Written Assessment per CCR Title 22 <br /> Applied Aerospace Structures, Inc., Stockton, CA 95206 2017 <br /> Tank 3, Reagent Mix Tank <br /> Vertical Cylindrical on Stand <br /> Material of Construction: LDPE <br /> Shell Height, in 40.00 <br /> Shell Diameter in 20.00 <br /> Working Volume, gal 49.00 <br /> S.G. of contents 1.05 <br /> Tank Wall Thickness, in 0.32 <br /> Total Weight of Tank and Contents, lbs. 495.00 <br /> Overturning Moment Arm, in 28.00 <br /> Resisting Moment Arm, in 10.00 <br /> Sds 0.69 <br /> Importance Factor 1.00 <br /> Fp, ASCE 7-10, 15.4-2 102.47 <br /> Overturning Moment inlbf 2869.02 <br /> Resisting Moment, inlbf 4950.00 <br /> Overturning Safety Factor - No Tension 1.73 <br /> Shear Strength of Anchor. Lbs. 3432.00 <br /> # of Anchors 4.00 <br /> Factor of Safety for Shear 133.98 <br /> Seismic/Anchoring findings: The tank as designed and operated and the <br /> containment area in which it is located are ae uately anchored and are <br /> seismical) sound. Initials: <br /> Strandberg Associates 1(866) 388-0404 rwaterguy(a-)rwaterguy.com 32 <br />