Laserfiche WebLink
we <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.siaov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ASCO POWER TECHNOLOGIES LP 705 N CARLTON AVE STOCKTON October 22 2015 <br /> Universal Waste <br /> 707 HSC 25201.16(e) Failed to manage aerosol cans in a manner that prevents the unauthorized release of waste o V o R ❑COS <br /> 708 HSC 25201.16(f) Failed to properly manage containers of waste aerosol cans ❑V ❑R ❑COS <br /> 709 HSC 25201.16(g) Failed to store used aerosol cans in an accumulation container ❑V ❑R ❑COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing ❑V ❑R ❑COS <br /> 711 HSC 25201.166) Failed to submit or amend notification for aerosol can processing ❑V In R o COS <br /> 712 CCR 66273.34 Failed to label universal waste to identify type of universal waste ❑V ❑R ❑COS <br /> 713 CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has been stored ❑V ❑R ❑COS <br /> 714 CCR 66273.36 Failed to train employees and maintain records on UW handling and emergency procedures ❑V ❑R ❑COS <br /> 715 CCR 66273.39 Failed to keep complete records of each shipment of universal waste for three years I ❑V n R o COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation o V ❑R o COS <br /> 3020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 3030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 3050 See below Unlisted AbandonmenUlllegal Disposal/Unauthorized Treatment violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments: <br /> Closure inspection conducted today. No hazardous wastes observed on site. According to Mr. Bill Venkus, the <br /> equipment still on site will be shipped as is to the new facility in North Carolina. This facility will be inactivated as t <br /> hazardous waste generator with SJC EHD. <br /> Disposal records were observed on site for the following closure wastes: <br /> -fluorescent tubes -latex paint <br /> -ethoxylated alcohols -alkylpolysiloxanes <br /> -aluminum chlorhydrate -petroleum distillates <br /> -sodium hydroxide / potassium hydroxide -paint related materials <br /> -used oil (lead/benzene liquid) -phosphoric acid <br /> -lead acid batteries <br /> ALL EHD STAFF TIME AO IATE TH FAILING TOCOMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE C RREN H URLYRATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By Received By(printed name and title): Date: <br /> (signature): Bill Venkus, Environmental Coordinator Q y22 <br /> Inspector Inspector(printed name and title): Ins for Ph e: <br /> (signatur STACY RIVERA, Senior REHS (209) 468-3440 <br /> Page 3 of 3 <br />