COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2200 - Hazardous Waste Program
>
PR0514115
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2020 10:11:37 AM
Creation date
10/31/2018 12:45:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514115
PE
2249
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Supplemental fields
FilePath
\MIGRATIONS\C\CORRAL HOLLOW\15999\PR0514115\COMPLIANCE INFO 2015.PDF
QuestysFileName
COMPLIANCE INFO 2015
QuestysRecordDate
2/14/2018 5:54:51 PM
QuestysRecordID
3615097
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2266
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Matrix Spike (MS) Recovery Statement <br />The percent recoveries (%R) obtained from the MS analyses are evaluated when the sample <br />concentration is less than four times (4X) the spike concentration added. The MS met the <br />recommended quality control acceptance criteria for percent recoveries for all applicable <br />analytes with the exceptions of antimony, lead, thallium and zinc. <br />Matrix Spike Duplicate (MSD) Recovery Statement <br />The percent recovery (%R) obtained from the MSD analyses are evaluated when the sample <br />concentration is less than four times (4X) the spike concentration added. The MSD met the <br />recommended quality control acceptance criteria for percent recoveries for all applicable <br />analytes with the exceptions of antimony, copper, lead and zinc. <br />MS/MSD Relative Percent Difference (RPD) Statement <br />The relative percent difference (RPD) obtained from the designated matrix spike duplicate <br />(MSD) is evaluated based on acceptance criteria of 20%. The RPD between qualifying elements <br />results in the MS and MSD were within the acceptance limits of 20% with the exception of <br />thallium. <br />Serial Dilution % Difference Statement <br />The serial dilution is used to assess matrix suppression or enhancement. Raw element <br />concentrations 25x the IDL/MDL for CVAA, 50X the IDL/MDL for ICP and 100X the <br />IDL/MDL for ICP -MS analyses are applicable for serial dilution assessment. All applicable <br />analytes met the established criteria of less than 10% difference (%D) with the exceptions of <br />chromium and copper. <br />Technical Information <br />Holding Time Specifications <br />GEL assigns holding times based on the associated methodology, which assigns the date and <br />time from sample collection of sample receipt. Those holding times expressed in hours are <br />calculated in the AlphaLIMS system. Those holding times expressed as days expire at midnight <br />on the day of expiration. All samples in this SDG met the specified holding time. <br />Preparation/Analytical Method Verification <br />All procedures were performed as stated in the SOP. Method SW -846 3050B is not a total <br />digestion technique for most samples. It is a very strong acid digestion that will dissolve almost <br />all elements that could become environmentally available. By design, elements bound in silicate <br />structures are not normally dissolved by this procedure as they are not usually mobile in the <br />environment. <br />Sample Dilutions <br />Dilutions are performed to minimize matrix interferences resulting from elevated mineral <br />element concentrations present in solid samples and/or to bring over range target analyte <br />concentrations into the linear calibration range of the instrument. The samples in ttY55 did <br />not require dilutions. <br />FEB C 9 z0a <br />ENVIRONMENTAL HEALTH <br />Page 14 of 39 <br />