Laserfiche WebLink
Rev date: 12.3,15 <br />Attachment 6. LLNL Violation Tracking Spreadsheet - Hazardous <br />Waste Generator <br />September - October 2015 <br />LLNL Site 300 <br />Violation <br />Regulation/Code <br />Violation Description <br />Inspection Report Action <br />Report Item #f <br />Violation Class___-_ <br />. . . . .......... . . . . . . ......... <br />Item <br />Status <br />712 <br />CCR 6627334 <br />Class 11 <br />FAILED TO LABEL UNIVERSAL WASTE TO IDENTIFY TYPE OF UNIVERSAL WASTE <br />. ...... <br />. . . . ...... <br />CCR 66273.34 Failed to label universal waste to identify type of universal waste. <br />The following observations were made during the inspection (a-c} <br />immediately label these <br />Universal waste shall be marked with the words "Universal Waste" and the type of waste (batteries, <br />wastes and ensure that all <br />mercury containing equipment, lamps, electronic devices, CRT's, CRT glass), Immediately label these <br />universal wastes are <br />wastes and ensure that all universal wastes are labeled with the required information. <br />labeled with the required <br />information, <br />At 865 Corp Yard, two fluorescent tubes were stored open and unlabeled. <br />Violation acknowledged and corrected. <br />a <br />See above. <br />Corrected the day of inspection. Transported to the 883 WAA for <br />managernent as Universal Waste. <br />. . ...... <br />Refer to Attachment 7, page 3. <br />At Corp Yard north of 865, there were electronics waste and a CRT stored on the ground and a pallet <br />Violation acknowledged and corrected. <br />b <br />including a microwave, a computer monitor, a keyboard, and lamps without a label. <br />See above. <br />Electronics waste vvas removed and managed as hazardous waste. <br />Refer to Attachment 7, page 4. <br />At building 874, electronics waste was stored on a pallet outside without a label. <br />LLNL requests SJCEHD to rescind the violation, <br />c <br />See above. <br />The electronics are usable equipment; therefore, 66273.34 does not apply, <br />Refer to Attachment 7, page 21, <br />713 <br />CCR 66273,35 <br />STORED UW ONSITE GREATER THAN ONE YEAR OR WAS UNABLE TO DEMONSTRATE THE TIME LJW HAS <br />Class 11 <br />BEEN STORED <br />CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has <br />been stored. <br />The following observations were made during the inspection: <br />Universal waste may be accumulated for no longer than one year from the date the universal waste was <br />Immediately dispose of <br />a <br />generated. The universal waste handier shall be able to demonstrate the length of time that the universal <br />this waste avid submit a <br />MsposA receipts for 113b, 713c to be submitted after waste transpoited <br />waste has been accumulated, Since it could not be demonstrated how long this waste was stored on site, <br />copy of the disposal <br />off-site, <br />immediately dispose of this waste and submit a copy of the disposal receipt to the EHD, <br />receipt to the EHD, <br />At 865 Corp Yard, two fluorescent tubes were stored open and unlabeled. <br />. . . . .... . ....... <br />Violation acknowledged and corrected. <br />b <br />See above. <br />Corrected the day of inspection. Transported to the 883 WAA for <br />management as Universal Waste. <br />Refer to Attachment 7, page 3. <br />RECEIVED <br />DEC 0 4 2015 <br />ENVIRONMENTAL <br />HEALTH DEPARTMENT RCRA Large Quantity Hazardous Waste Generator Inspection Report 12 <br />