San Joaquin County <br />Environmental Health Department <br />DEC 0 4 2015 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www,sj oq v_org/ehd <br />HEALTH DEPAftiQ!wground Petroleum Storage Act Inspection Deport <br />Facility Name: Facility Address: <br />Date: <br />Lawrence Livermore National Lab - Site 300 15999 W CORRAL HOLLOW RD Tracy <br />September 30 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />713 <br />CFR 112.8(c)(6) Failed to perform scheduled tank tests and inspections by appropriately qualified personnel. <br />The Diala oil tank for building 801 was not tested for integrity. According to the SPCC Plan, visual inspections will be <br />used for integrity testing unless problems are detected. The monthly tank inspection records being maintained by Mr. <br />Tom McWilliams, the building APSA "operator", have marked for many months that there is liquid visible in the <br />secondary containment or berm and that the exterior coating is bubbling, cracked, or damaged. When questioned <br />about what kind of "problems" noted during the monthly inspections would trigger additional integrity testing, Mr. <br />McWilliams stated that he monitors the tank inventory levels and would take action if the levels indicated a loss of <br />product. Each aboveground container shall be tested and inspected for integrity on a regular schedule and whenever <br />repairs are made, The qualifications of personnel performing tests and inspections, frequency and type of testing and <br />inspections that take into account container size, configuration, and design shall be determined in accordance with <br />industry standards. Examples of these integrity tests include, but are not limited to: visual inspection, hydrostatic <br />testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive <br />testing. Comparison records and other records of inspections and tests must be maintained on site. Immediately <br />conduct the necessary testing and submit a copy of the test results to the EHD, or provide equivalence as allowed by <br />CFR 112.7(a)(2). <br />This is a Class II violation. <br />CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br />717 <br />Liquid level sensing devices have not been tested. According to Mr. Tom McWilliams, the APSA "operator" at building <br />801, the liquid level sensing devices are looked at for determining inventory levels, but are not tested or checked for <br />accuracy. Procedures and frequency of testing for these devices were not addressed in the Spill Prevention, Control, <br />and Countermeasure (SPCC) plan. Liquid level sensing devices must be installed in accordance with CFR 112.8 and <br />shall be regularly tested to ensure proper operation. Immediately conduct all necessary testing of liquid level sensing <br />devices, or provide equivalence as allowed by CFR 112.7(a)(2). <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving this report. <br />The inspection was conducted on the following dates: <br />September 30, 2015 <br />October 1, 2015 <br />October 5, 2015 <br />October 15, 2015 <br />October 19, 2015 <br />The final checklist was provided to John Scott on October 19, 2015. The report was completed on October 26, <br />2015. <br />Received by <br />(initial)mo��d <br />Inspector: <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />Date: <br />09/30/2015 <br />Page 5 of 6 <br />