My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2200 - Hazardous Waste Program
>
PR0513773
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:48:16 PM
Creation date
10/31/2018 4:25:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513773
PE
2220
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0513773\COMPLIANCE INFO 2001 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2001 - 2016
QuestysRecordDate
12/19/2017 5:47:57 PM
QuestysRecordID
3749376
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, Califomia95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.s clov-o[g/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JIMCO TRUCK PLAZA` I 'ONTAGE RD. RIPON March 18, 201 <br /> Preparedness and Prevention <br /> VCCR66262.34(d)(2)(d)(2) Facility not maintained to minimize the release of a hazardous waste ❑V ❑ R ❑COS <br /> (d)(2) Failed to maintain required emergency equipment ❑V ❑R ❑COS <br /> (d)(2) Failed to maintain all communication oralarm systems,spill control,or decontamination equipment ❑V ❑R ❑COS(d)(2) Failed to maintain adequate aisle space for unobstructed response to emergencies ❑V ❑R ❑COS <br /> Container Management <br /> 401 CCR 66262.34(d)(2) Felled to store hazardous waste In a container that Is In good condition ❑V ❑R ❑COS <br /> ❑V ❑R o COS <br /> 402 CCR 66262.34(d)(2) Failed to store hazardous waste in a compatible container <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardouswaste containers closed except when adding or removing hazardouswaste .V ❑R ❑COS <br /> 404 CCR 66262.34(d)(2) Failed to inspect hazardous waste storage areas at least weekly ❑V ❑R ❑COS <br /> o OR ❑COS <br /> 405 CCR 66262.34(d)(2) Failed to manage incompatible wastes in containers properly <br /> 406 CCR 66261.7(f) Contaminated container not marked with date emptied or managed within one year of being emptied ❑V ❑R ❑COS <br /> 407 CCR66262.34(e)(1)(A) Satellite accumulation container not located near point of generation or under control of operator ❑V ❑R ❑COS <br /> 408 CCR 66262.34(e)(2) Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely HW)per waste stream ❑V ❑R o COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank <br /> ❑V o ❑COS <br /> 502 CCR 66262.34(d)(2) Tank system inspections of discharge systems,monitoring equipment,and tank levels not done daily o V OR o COS <br /> 503 CCR 66262.34(d)(2) Tank system inspections of construction materials,fixtures,and surrounding areas not done weekly ❑V ❑R ❑COS <br /> 504 CCR 66262.34(d)(2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment ❑V ❑R ❑COS <br /> Labeling and Storage <br /> ❑V o ❑COS <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days <br /> 602 CCR 66262.34(e)(1)(B) Stored satellite accumulated waste on site longerthan one year or 180 days after fill date ❑V ❑R ❑COS <br /> V oR ❑COS <br /> 603 CCR 66262.34(e)(1)(C) Felled to mark initial accumulation start date on satellite containers <br /> ❑ <br /> ❑V OR ❑COS <br /> 604 CCR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days <br /> ■V o ❑COS <br /> 605 CCR 66262.34(f) Failed to completely label containers or tanks of hazardous waste <br /> 606 CCR 66266.81(a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption o V ❑R ❑COS <br /> ❑V u ❑COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not property managed and labeled <br /> ❑V UR ❑COS <br /> 608 CCR 66266.130 Failed to properly manage used oil and fuel fitters <br /> ❑V ❑R ❑COS <br /> 609 HSC 25143.2,25143.9 Failed to meet requirements for claimed excluded recyclable materials <br /> Universal Waste <br /> 701 CCR 66273.32(a) Failed to notify the EPA RA to obtain an EPA ID#priorto accumulating>5000kg of UW ❑V n R o COS <br /> 702 CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW ❑V ❑R o COS <br /> 703 CCR 66273.33(a) Failed to store UW batteries in a manner that prevents breakage and release to the environment ❑V ❑R ❑COS <br /> 704 CCR 66273.33(b) Failed to property manage universal waste lamps <br /> ❑V o ❑COS <br /> 705 CCR 66273.33(c) Failed to properly manage mercury containing universal waste <br /> ❑V o ❑COS <br /> Phone: - Date: <br /> Received by Inspector: 03/18/2015 <br /> (initial): ELENA MANZO, REHS (209) 953-7699 <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.