Laserfiche WebLink
The Teflon bailer used to purge the wells and collect the water samples was thoroughly <br /> decontaminated prior to each use to prevent cross-contamination of samples Decontamination <br /> of the bailer consisted of an initial wash with an alconox/potable water solution followed by a <br /> potable water rinse, and a final rinse with distilled water The thin nylon line used to lower the <br /> bailer was removed and discarded after each use <br /> All purge water from the wells and decontamination rinsate was transferred to a 700-gallon poly- <br /> tank located onsite Analytical results well be used to evaluate the disposition of the water. <br /> All field activities were performed in accordance with WESTON's site specific health and safety <br /> plan, which was available onsite during field activities A safety meeting was held with field <br /> personnel prior to starting work in order to review anticipated safety hazards and emergency <br /> procedures The field work for this project was performed under Level D personal safety <br /> protection <br /> 1 <br /> 1 <br /> 1 <br />' STKCIRPTS44REG3QTR WP A - 4 1111?192 <br />