My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2012-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 9:51:31 AM
Creation date
11/1/2018 10:44:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2012-2013
FileName_PostFix
2012-2013
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Don Mukai - 4 - January 23, 2013 <br />Kit, State Registered Professional Engineer Approval letter, and the documentation <br />included in Bravo's request for review letter dated August 12, 2012. A California <br />registered Professional Engineer has reviewed documentation containing the CONV <br />Retrofit Plate Kit's specifications and installation procedures and has concluded that the <br />CONV Retrofit Plate Kit is acceptable for retrofitting the CONV-B2000 to accommodate <br />existing conduit that protrude through concrete on the exterior of the existing UDC (See <br />Enclosure 3). <br />Conditions of Approval for the CONV Retrofit Plate Kit <br />Based on the Professional Engineer's review and the documentation submitted, we are <br />granting approval of the CONV Retrofit Plate Kit under the following conditions: <br />All conditions listed above for the CONV-B2000 apply and must be met. <br />Materials and procedures employed in the CONV Retrofit Plate Kit shall be <br />identical to those indicated in the Installation Manual for a Bravo CONV-Retrofit- <br />Plate Kit dated September 24, 2012. <br />This kit comes in several sizes in order to accommodate various dimensions and <br />layouts of conduit in dispensers. Instructions for all existing and future retrofits of <br />the CONV Retrofit Plate Kit shall be made available upon request of the State <br />Water Board. <br />Only qualified individuals meeting the requirements of CCR, Title 23, section <br />2715(h), including training and certification by the manufacturer (S. Bravo <br />Systems, Inc.), are allowed to install the CONV Retrofit Plate Kit when authorized <br />by Bravo in an official correspondence signed by a company representative on a <br />per qualified individual, per site and per application basis. <br />The qualified individual must use only the Bravo supplied CONV Retrofit Plate Kit <br />components and materials tailored for that specific installation on a per site and <br />per application basis. <br />The qualified individual must follow the Bravo CONV Retrofit Plan: Plan for <br />Control of the CONV Retrofit Plate dated August 21, 2012 and any written <br />instructions supplied by Bravo for that specific installation procedure.
The URL can be used to link to this page
Your browser does not support the video tag.