Doug O'Neal • • <br /> April 24, 2002 <br /> Page 3 <br /> assessment, wells SMW-1 through SMW-6 are identified as monitoring wells to be sampled <br /> under MRP 5-01-269 (effective as of December 7, 2001). <br /> The 2001 Annual Report and a December 14, 2001 letter from the facility indicate that well <br /> TP-3A could not be sampled during the fourth quarter 2001 sampling event because a bailer <br /> became lodged in the well casing. GSU would appreciate an update on the status of this <br /> well. <br /> In January 2002, the facility provided a status report (Dudek 2002) on the protective <br /> measures for the monitoring network that were to be implemented after DTSC approval <br /> (DTSC 2001b). GSU would appreciate an updated status report regarding the protective <br /> measures. <br /> As summarized in Table 1 (attached), elevated final turbidity measurements were identified <br /> in four wells during the fourth quarter 2001. However, only well KEW-4U is recommended <br /> for redevelopment. As discussed in DTSC (2002), wells with elevated turbidity <br /> measurements (e.g., greater than 5 nephelometric turbidity units (NTU)) require an <br /> adjustment in the purging/sampling procedures or maintenance (e.g., redevelopment). <br /> Wells that cannot consistently produce low turbidity groundwater samples, representative of <br /> subsurface conditions, must be decommissioned and replaced. <br /> Table 3 and Appendix E of the 2001 Annual Report provide tabulated summaries of volatile <br /> organic compounds detected in groundwater samples. To facilitate GSU's review, Table 3 <br /> of the 2002 Annual Report should summarize all analytical results (detects and non-detects) <br /> for samples collected during the 2002 reporting year. It would be helpful if the 2002 Annual <br /> Report includes a comprehensive tabulated summary of historical analytical data (including <br /> non-detected results). This tabulated summary could be submitted either as an appendix or <br /> electronically (Excel format). <br /> REFERENCE <br /> DTSC. 2001 a. GSU Comments on Summary of Groundwater Quality Kearney-KPF Facility, <br /> Stockton, California, October 2000 and 2000 Annual Report. July 11, 2001. <br /> DTSC. 2001 b. Technical Issues Associated With Responses to Potential Violations Cited by <br /> DTSC, Groundwater Operation and Maintenance Inspection, Former Kearney-KPF Facility, <br /> Stockton, California. November 2, 2001. <br /> DTSC. 2002. GSU Comments on Water Quality Sampling and Analysis Plan, Former Kearney- <br /> KPF Facility, 1624 East Alpine Avenue, Stockton, CA 95295. February 21, 2002. <br /> Dudek and Associates (Dudek). 2002. Update on Status of Protective Measures for <br /> Threatened Wells at Former Kearney-KPF Facility. January18, 2002. <br />